EN
8
To connect the control panel, open the 4 screws of the panel and mount the wires
according to the above diagram. The connection is made by opening the screw on ruler,
inserting the wire to a length of at least 1 cm and then tightening the screw.
- The black wire (numbered 4) will connect in the third hole from left to right.
- The blue wire (numbered 5) will connect in the fourth hole from left to right.
- The brown wire (numbered 6) will connect in the fifth hole from left to right.
- The marked green / yellow wire will connect in the sixth hole.
Do not lift the pump, holding the electric cable or the discharge hose, none of them
withstand the firing forces produced by the weight of the pump.
1. Lower the pump to the bottom of the liquid container. To do this use a strong rope,
fixed to the pump handle. The pump can operate and be suspended from the rope. 2.
Connect the power cord to the outlet.
6. COMMISSIONING
Starting and stopping
The pump starts by connecting the power cord to the outlet.
The pump stops, disconnecting the power cord from the outlet.
Careful! If the water level drops too much in the well, the deep pump runs on land and
deteriorates. During operation, make sure that the water level is high enough to avoid the
operation of the pump on land.
Damage caused by land operation is not covered by the warranty.
Overwork protection.
This submersible pump is provided with an overload protection that stops the pump
automatically when overloaded. If overload protection is triggered :
1. Unplug the plug.
2. Eliminate the cause of overload.