www.ruptela.com
[email protected] | +370 5 2045030
7
Cut the remaining chord as close to the cap as
possible.
Insert the cap end onto the cap.
Put the measurement head on the probe.
Insert the probe into the tank and orientate the
signal cable towards where it will be going out.
Note the position of the signal cable on the flange.
Make a marking 45 degrees counter-clockwise
from the cable.
Route the 7 m extension cable to the cabin.
Connect the cable to the power supply and to the
FM device (see Appendix B).
Insert
Cut
Cable direction
45°
Mark position
Mark stripe on flange
Route 7 m cable