INTRODUCTION 

These instructions provide the necessary information concerning the installation, operation and proper 
maintenance of the arm. The user should read the manual each time before installing and starting to operate 
the device. The arm has been designed for professional use, and thus it should be used in this way. Use the 
device for extracting dry dust only.  
Attention:  The unit is not intended for the extraction of the following materials: inflammable substances, 
explosive and inflammable solvents, welding smoke, burning materials, petrol, lubricating oil, alcohol, paints 
and solvents with an ignition temperature of over 60

°

C. Failure to follow this instruction constitutes a fire and 

explosion hazard. The accumulation of dust while cleaning surfaces coated with paint with an uncompleted 
hardening cycle may result in spontaneous ignition. At a minimum of once a year the manufacturer or 
authorised service personnel should perform a technical inspection of the unit. 
NTS Sp. z o.o. [Ltd.] will not be held responsible for any damage, direct or indirect, due to failure to follow the 
guidelines provided in these instructions. 

 
 
 

SAFETY STANDARDS 
Attention:  
Apply the following measures during the operation of the arm in order to avoid fire, electric 
shock, injuries. Read the manual thoroughly before starting to use the arm, and maintain the device 
carefully. 

 
 
 

GENERAL SAFETY RULES 

-

 

Apply special hearing protection in case the  emitted noise level exceeds 85 dB (A). 

-

 

Pay special attention to operating conditions. Never expose the arm to rainwater, do not install it 
in a humid or wet place, in an atmosphere containing gas vapours, or in a place, where inflammable 
liquids are stored. 

-

 

Protect yourself against electric shock. Avoid contact with earthed objects or surfaces (e.g. metal 
parts, pipes, radiators, furnaces, etc.). 

-

 

Never leave the device in place accessible for children or unauthorised persons. In particular, 
make sure that no unauthorised person has access to the unit. 

-

 

Do not overload the arm with excessive loads and accessories, never install more than two tools. 
When the unit is used in an appropriate way, maximum efficiency and safety is guaranteed.  

-

 

Always wear suitable clothes. Avoid clothes, which are too loose, do not wear laces, chains, etc., 
which could become entangled in the machine elements during work. It is recommended to use 
gloves and boots with antislip soles. In the case of long hair, tie it with an elastic band. 

-

 

Use safety goggles. We recommend using a dust-mask in very dusty places. 

-

 

Maintain the arm well. To ensure its safe use, the tool should always be clean and properly started. 
Always strictly follow the maintenance instructions, have authorised service personnel carry out any 
possible repairs, as this guarantees the use of original spare parts only. Failure to follow these rules 
may result in serious injuries and damage to objects. 

-

 

Always cut off the power supply before any maintenance or repair operation. 

-

 

Always apply special precautions. Operate carefully and reasonably, do not fool around during 
work. 

-

 

Check damaged parts. Carefully inspect if the machine safeguards or parts are not damaged and if 
they function properly. Check the synchronization of the parts in motion, their possible seizing up, 
cracks, mounting quality, and any other situation, which may result in the faulty operation of the 
machine. 

-

 

Observe these instructions. 

Summary of Contents for HB 525

Page 1: ...1 HB 525 HB625 PAT Multifunctional swing arm OPERATING AND MAINTENANCE INSTRUCTIONS ...

Page 2: ...et place in an atmosphere containing gas vapours or in a place where inflammable liquids are stored Protect yourself against electric shock Avoid contact with earthed objects or surfaces e g metal parts pipes radiators furnaces etc Never leave the device in place accessible for children or unauthorised persons In particular make sure that no unauthorised person has access to the unit Do not overlo...

Page 3: ...r compressed air with flow capacity 1500 l min max pressure 8 bar 1 quick connection for dry compressed air with pressure regulator and manometer one double dust extraction coupling 1 16 A electric socket 2 16 A electric socket 3 Lighting switch 4 Lamp with 300 W halogen bulb 5 Voltage indicator 6 Fuse 7 MAN 0 AUT switch 8 Safety cut out switch 9 Compressed air connection terminal 10 Dry compresse...

Page 4: ... 16 mm depth 90 mm This hole matches the upper right hole in the yoke Fig 3 Place the pin and slightly screw it in Mark the other holes using a spirit level to get them parrallel Fig 4 Move the yoke and start drilling place pins and fasten all elements after checking they are parallel with a spirit level Before installing the arm check that the pins firmly hold the arm base Fig 5 Fig 6 4 FASTENING...

Page 5: ...5 mm 2 cable for connection with the turbine control cable NOTE REGARDING THE HB525P HB625P ARM One 3 x 2 5 mm 2 cable which supplies the whole arm One 2 x 1 5 mm 2 cable for connection with the turbine control cable ATTENTION All 3 x 2 5 mm 2 cables which supply the arm should be connected to magnetothermal differential switch 6Ka 30 mA 16 A Only authorised and specialised personnel may perform t...

Page 6: ...ND PNEUMATIC CONNECTIONS DIAGRAM str 6 WIRING DIAGRAM str 8 PNEUMATIC CONNECTIONS DIAGRAM str 10 WIRING DIAGRAM WITH AUTOMATIC PNEUMATIC CONTROLLER str 11 WIRING DIAGRAM str 13 PNEUMATIC CONNECTIONS DIAGRAM str 14 ...

Page 7: ...ith the electrical system or compressed air supply system b mechanical damage caused by operation inconsistent with the enclosed operating instructions c any damage caused by operation inconsistent with the enclosed operating instructions d damage being the consequence of repairs carried out in any place other than warranty repair centre e operation actions specified in the operating instructions ...

Page 8: ...8 NOTES ...

Page 9: ...9 Poland 05 083 Zaborów Borzęcin DuŜy ul Warszawska 749 tel 022 752 06 00 fax 022 752 05 92 e mail nts nts com pl http www nts com pl ...