Runxin J120 Series User Manual Download Page 13

 

11 

A1 

A2 

A3 

A4 

 

A5 

B. Parameter set in background 

Parameters  could  be  set  in  background:  Set  Mode,  Set  Valve  Model,  Set  Service  Days,  Set 

Backwash, Set Fast Rinse(For water filter setting) 

a) In the H1 interface, select the “Mode” and press

, as the figure A1 shows. Press 

  or 

  to 

select the mode that you need. Select Filter for water filter. After that, Press 

to save the setting 

and turn back to H1; or press

to turn back to H1 without saving the setting.     

b) In the H1 interface, select “Set Valve Model” and press

, as the figure A2 shows. Press 

  or 

  to select the matched valve type. Press 

to save the setting and turn back to H1; or press 

to turn back to H1 without saving the setting. 

c) In the H1 interface, select “Set Service Days” and press , as the figure A3 shows. Press

  or 

  to select the days that you need. Press 

to save the setting and turn back to H1; or press 

to turn back to H1 without saving the setting. 

d) In the H2 

interface, select “Set Backwash” and press

, as the figure A4 shows. Press

  or 

   

to select the backwash time that you need. Press “

”to save the setting and turn back to H1; or 

press “

” to turn back to H1 without saving the setting. 

e) In the H2 

interface, select “Set Fast Rinse” and press

, as the figure A5 shows. Press 

  or 

  to select the fast rinse time that you need. Press 

to save the setting and turn back to H1; or 

press 

  to turn back to H1 without saving the setting. 

Illustration: For this 

series products, you don’t need set the background parameters.  All of them 

are  already  set  by  manufacturer  according  to  the product  type  and  specification.  If  you  have  to 

reset, please makes sure the work is done by professional. 

 

Parameter Set (Only for factory or professional dealer) 

Model 

Backwash Time (Minute) 

Fast Rinse Time (Minute) 

Regeneration Days (Day) 

RL-J50 

Set Fast Rinse 

3Min. 

Summary of Contents for J120 Series

Page 1: ...ease read this manual in details before using the device and keep it properly in order to consult in the future Note The design and specifications are subject to the changes without prior notice We re...

Page 2: ...eters 6 1 Parameter Table 6 2 Working Condition 7 Function and Characteristics 8 Installation 8 1Installation Condition 8 2Installation and Connection 8 3Control Valve Set and Usage The Function of Co...

Page 3: ...good filtering effect automatic rinsing and long life time It removes the harmful things efficiently such as residual chlorine abnormal smell rust mud etc After the active carbon disabled the device c...

Page 4: ...P Tank 5 Strainer 3 Riser Pipe 6 Quartz Sand 4 Specification and Active Carbon Volume Model FRP Tank Size h mm FRP Tank Model Active Carbon Volume L Quartz Sand Volume L RL J50 258 330 1013 5 4 RL J60...

Page 5: ...1500 5 RL J180 1800 6 6 2 Working Condition Working Condition Working Pressure 0 15MPa 0 4MPa Water Temperature 5 38 Working Environment Environment Temperature 4 40 Relative Humidity 95 25 Electrical...

Page 6: ...hold the and buttons for 5 seconds to unlock This function can avoid incorrect operation 8 Installation 8 1 Installation Condition Place the product on the flat surface that can bear the weight more...

Page 7: ...let is closed connect it with the device All of pipeline that used should meet the relevant regulations and the installation should accord with the local installation rules When install please keep a...

Page 8: ...soft tube and metal clamp from the spare part kit make the drain connector insert into soft tube as much as possible the insert part is no less than 20 mm In winter the temperature is low use the hot...

Page 9: ...g the gravity from the pipeline Notice Please make sure the drain line and overflow line is connected and close to sewer making the waste water flow into the sewer rapidly 8 3Control Valve Set and Usa...

Page 10: ...ample If the quality of outlet water fails after unlocking the buttons press in service status it will start regeneration cycles instantly During the cycle of regeneration if you want finish current s...

Page 11: ...both and for 5 second until lights off 1 Press and enter into the interface of Set Filter Para as the figure J1 shows The item of Set Time of Day will be selected by system automatically 2 Then press...

Page 12: ...te value 4 Lastly press and hear a sound Di then finish adjustment J3 Background parameter inquiry and setting Operated by manufacturer or professional dealer A Enter background mode Within 6 seconds...

Page 13: ...u need Press to save the setting and turn back to H1 or press to turn back to H1 without saving the setting d In the H2 interface select Set Backwash and press as the figure A4 shows Press or to selec...

Page 14: ...he first time usage Press to back to Service status open the faucet to check if the water is clean If the water is still carbon color it needs more backwash and fast rinse Illustration The purpose of...

Page 15: ...times of backwash and fast rinse 10 5 If the water demand is increasing Compared to usual demand or the raw water quality is reducing please add the backwash and fast rinse times 10 6 As the product...

Page 16: ...he valve body B Close the bypass valve until the power is on 7 All indicators display on display board A Wiring of display board with control board fails to work B Main control board is faulty C Adapt...

Page 17: ...ctive carbon the length of riser tube should be neither higher nor 10mm lower than the tank top opening height and its top end should be rounded to avoid damage of O ring inside the valve 2 Avoid floc...

Page 18: ...ric shock earthquake etc The damage is result from the disassembly or refits by user or repair by non scheduled maintenance unit The damage is caused by the improperly transportation installation usag...

Reviews: