Runxin J120 Series User Manual Download Page 10

 

A. 

  Button lock indicator 

  Lights on, indicating the buttons are locked. At this moment, press any single button will not 

work (No operation in one minute, 

  will light on and lock the buttons.) 

Solution: Press and hold both 

  and 

  for 5 seconds until the 

  lights off. 

B. 

 Menu/Confirm button 

Press 

  under the service status, the system turns into setting interface. Select the item and 

inquire the value. 

Under  inquiry  status,  press 

  and  the  digits  flash.  It  turn  into  setting  interface,  and  you  can 

adjust the parameters by press 

  and 

After  the  setting,  press 

  and  turn  into  setting  interface  by  saving  the  settings  with  a 

Di

 

sound.   

C. 

 Manual/Return button 

Press 

  under the service status, the system will finish current status and turn into next status 

immediately. (For example: If the quality of outlet water fails, after unlocking the buttons, press 

   

in service status, it will start regeneration cycles instantly; During the cycle of regeneration, if you 

want finish current steps in advance, press 

    and it will turn into next step at once.) 

Press 

  under the inquiry status, the system will turn back to service status interface; Press 

 

under the setting status, the system will turn back to inquiry status. 

Under the setting status, press 

  and the system will turn back to inquiry status without saving 

the setting value.   

D. Down 

  and Up 

 

Under the inquiry status, press 

  or 

  to view all values. 

Under the setting status, press 

  or 

  to adjust values. 

Press and hold both 

  and 

  for 5 seconds to lift the button lock status. 

 

Parameter Setting (By users) 

Item 

Parameter Set Arrange 

Factory Default 

Time of Day 

00:00

23:59 

Current time 

Rinsing Time 

00:00

23:59 

02:00 

Press and hold both 

  and 

  for 5 seconds under the service status, till the 

  lights off. 

Summary of Contents for J120 Series

Page 1: ...ease read this manual in details before using the device and keep it properly in order to consult in the future Note The design and specifications are subject to the changes without prior notice We re...

Page 2: ...eters 6 1 Parameter Table 6 2 Working Condition 7 Function and Characteristics 8 Installation 8 1Installation Condition 8 2Installation and Connection 8 3Control Valve Set and Usage The Function of Co...

Page 3: ...good filtering effect automatic rinsing and long life time It removes the harmful things efficiently such as residual chlorine abnormal smell rust mud etc After the active carbon disabled the device c...

Page 4: ...P Tank 5 Strainer 3 Riser Pipe 6 Quartz Sand 4 Specification and Active Carbon Volume Model FRP Tank Size h mm FRP Tank Model Active Carbon Volume L Quartz Sand Volume L RL J50 258 330 1013 5 4 RL J60...

Page 5: ...1500 5 RL J180 1800 6 6 2 Working Condition Working Condition Working Pressure 0 15MPa 0 4MPa Water Temperature 5 38 Working Environment Environment Temperature 4 40 Relative Humidity 95 25 Electrical...

Page 6: ...hold the and buttons for 5 seconds to unlock This function can avoid incorrect operation 8 Installation 8 1 Installation Condition Place the product on the flat surface that can bear the weight more...

Page 7: ...let is closed connect it with the device All of pipeline that used should meet the relevant regulations and the installation should accord with the local installation rules When install please keep a...

Page 8: ...soft tube and metal clamp from the spare part kit make the drain connector insert into soft tube as much as possible the insert part is no less than 20 mm In winter the temperature is low use the hot...

Page 9: ...g the gravity from the pipeline Notice Please make sure the drain line and overflow line is connected and close to sewer making the waste water flow into the sewer rapidly 8 3Control Valve Set and Usa...

Page 10: ...ample If the quality of outlet water fails after unlocking the buttons press in service status it will start regeneration cycles instantly During the cycle of regeneration if you want finish current s...

Page 11: ...both and for 5 second until lights off 1 Press and enter into the interface of Set Filter Para as the figure J1 shows The item of Set Time of Day will be selected by system automatically 2 Then press...

Page 12: ...te value 4 Lastly press and hear a sound Di then finish adjustment J3 Background parameter inquiry and setting Operated by manufacturer or professional dealer A Enter background mode Within 6 seconds...

Page 13: ...u need Press to save the setting and turn back to H1 or press to turn back to H1 without saving the setting d In the H2 interface select Set Backwash and press as the figure A4 shows Press or to selec...

Page 14: ...he first time usage Press to back to Service status open the faucet to check if the water is clean If the water is still carbon color it needs more backwash and fast rinse Illustration The purpose of...

Page 15: ...times of backwash and fast rinse 10 5 If the water demand is increasing Compared to usual demand or the raw water quality is reducing please add the backwash and fast rinse times 10 6 As the product...

Page 16: ...he valve body B Close the bypass valve until the power is on 7 All indicators display on display board A Wiring of display board with control board fails to work B Main control board is faulty C Adapt...

Page 17: ...ctive carbon the length of riser tube should be neither higher nor 10mm lower than the tank top opening height and its top end should be rounded to avoid damage of O ring inside the valve 2 Avoid floc...

Page 18: ...ric shock earthquake etc The damage is result from the disassembly or refits by user or repair by non scheduled maintenance unit The damage is caused by the improperly transportation installation usag...

Reviews: