6
PREcIsIon tooLs
GB
I english
the RsH 1300 is designed according to protective class II.
Prior to putting the tool into operation, check the mains voltage for conformity with the requirements of the tool’s nameplate. Voltage variations
b 6 % and – 10 % are permissible. the tool includes a start-up speed limiter to prevent fast expulsion fuses from unindented responding.
only use extension cables with a sufficient cross-section. A cross-section which is too small could cause a considerable drop in performance and
anoverheating of machine and cable.
Recommended minimum cross sections and maximum cable lengths:
For manual drilling, the RSH 1300 may be used only together with its additional handle which comes with the tools. Place it on the gearing collar
from the front and fix it by counterclockwise rotation.
Electrical connection
Additional Handle
the slip clutch served for compensation of shocks and overload.
to keep its functionability, it should not slip for more than 2 seconds.
In case of excessive wearing, it can be replaced by an authorized service centre.
switching on and oFF
short-time operation:
on: Press the on/oFF switch
oFF: Release the on/oFF switch
Long-time operation:
on: Keeping the on/oFF switch pressed, push in the arrestor button.
oFF: Press and release the on/oFF switch again.
Attention!
Use the arrestor button only during operation with drill rig. Its use during manual operation is not allowed.
If the machine stops for any reason or due to power failure, immediately release the arrestor button by pressing the
on/oFF switch.
the RsH 1300 is equipped with an electronic switch. With this switch the speed can be regulated according to the pressure on the button.
only use the electronic switch when you want to start or stop the machine in order to avoid material splashing around. A permanent use with reduced
speed can cause an overload because the motor then gets less cooling air and therefore the machine will be overheated much faster.
safety clutch
cross section in sq. mm 1.5
cross section in sq 2.5
Mains voltage 110 V
20,0 m cable lengths
40,0 m cable lengths
Mains voltage 230 V
50,0 m cable lengths