Indicator
Panel Identification
Status
Meaning
POE state indicator
(only
for
S3760E-48P
and
the POE indicator is
solid yellow)
1~48
Off
The POE is not powered on.
Solid green
The POE has been powered on.
Solid yellow
The POE is overloaded, and is not powered on.
Solid red
The port POE does not supply power.
10/100Mbps RJ-45
port indicator
1~48
Off
The port is not connected to a link.
Solid green
The 100 M link that the port connects to is Up.
Blinking green
Data at a rate of 100 M are being transceived at
the port.
Solid yellow
The 10 M link that the port connects to is Up.
Blinking yellow
Data at a rate of 10 M are being transceived at
the port.
1000Mbps SFP
port indicator
49F, 50F
Off
The port is not connected to a link.
Solid green
The 1000 M link that the port connects to is Up.
Blinking green
Data at a rate of 1000 M are being transceived at
the port.
Solid yellow
The 100 M link that the port connects to is Up.
Blinking yellow
Data at a rate of 100 M are being transceived at
the port.
1000Mbps RJ-45
port indicator
49, 50
Off
The port is not connected to a link.
Solid green
The 1000 M link that the port connects to is Up.
Blinking green
Data at a rate of 1000 M are being transceived at
the port.
Solid yellow
The 100 or 10 M link that the port connects to is
Up.
Blinking yellow
Data at a rate of 100 or 10 M are being
transceived at the port.
1.5 Extension Modules
The RG-S3760E series switch support the following modules: M3000E-02SFP/GT, M3000E-STACK.
The M3000E-02SFP/GT module is used to extend 2 fiber/copper combo ports. The M3000E-STACK module is used
for the RG-S3250E switch stack.
[
Note
]: For the detailed description about those two modules, see
Switch Extension Module Usage Guide
.