Ruijie RG-RAP1200 Series Hardware  Installation And Reference Manual Download Page 10

·

 

Hardware Installation and Reference Guide                                                                                          Installing the Access Point 

 

 

3  Installing the Access Point 

 

Make sure you have carefully read Chapter 2, and be sure that the requirements set forth in  Chapter 2 have been 

met. 

3.1  Installation Flowchart 

 

3.2  Before You Begin 

Before installing the AP, verify that: 

 

The installation site provides sufficient ventilation for the AP.   

 

The installation site meets temperature and humidity requirements.   

 

The installation site is equipped with a proper power supply.   

 

Network cables are in place.   

 

The installation site meets all described requirements.   

 

The custom AP meets customer requirements.   

3.3  Precautions 

To avoid damage to the AP, observe the following safety precautions: 

 

Do not power on the device during installation. 

 

Install the device in a well-ventilated location. 

 

Do not subject the device to high temperatures. 

 

Keep away from high voltage cables. 

 

Install the device indoors. 

 

Do not expose the device in a thunderstorm or strong electric field.     

 

Keep the device clean and dust-free.   

Summary of Contents for RG-RAP1200 Series

Page 1: ...Ruijie RG RAP1200 F Series Access Points Hardware Installation and Reference Guide 1 00...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Page 4: ...g n 2 4 GHz to 2 4835 GHz 802 11a n ac 5G 5 15 GHz to 5 35 GHz 5 47 GHz to 5 725 GHz 5 725 GHz to 5 850 GHz Country specific Antenna PCB built in antenna Spatial Streams 2 4GHz 2 streams 2x2 MIMO 5GHz...

Page 5: ...o 70 C 40 F to 158 F Humidity Operating 5 to 95 RH non condensing Storage 5 to 95 RH non condensing Installation Ceiling wall mount in a 86 type faceplate IP Rating IP41 Safety Standards GB4943 EN IEC...

Page 6: ...is not receiving power Solid blue N A Normal operation Blinking 0 5Hz Normal operation but the AP is not connected to Ruijie Cloud Fast blinking 10Hz Possible cases 1 Restoring the factory default se...

Page 7: ...ot subject the AP to unstable voltage vibration and noises Keep the installation site dry Installing the device near sea is not recommended Keep the AP at least 500 meters away from the seaside and do...

Page 8: ...al leakage and sometimes may lead to change of mechanical properties of materials and corrosion of metal parts Low relative humidity may dry and shrink insulation sheets and cause static electricity t...

Page 9: ...ping pliers punch down tool Meter Multimeter bit error rate tester BERT The listed tools are customer supplied 2 8 Unpacking the Access Point Package Contents Items Verify that all parts are installed...

Page 10: ...and humidity requirements The installation site is equipped with a proper power supply Network cables are in place The installation site meets all described requirements The custom AP meets customer...

Page 11: ...asten the device tightly 3 4 Installing the Access Point 1 Loosen screws on the 86 type faceplate that is mounted on the wall Figure 3 1 Loosen Screws on the Faceplate 2 Connect the Ethernet cable to...

Page 12: ...bending the cable in a small radius close to the connector Ruijie recommends that you do not use Ethernet cables with protective sleeves as they could make installation of Ethernet cables more diffic...

Page 13: ...or the cabinet After installation make sure that the front and rear cabinet doors easily close Make sure the cabinet is stable and level Make sure the device and all cables are securely fastened in th...

Page 14: ...iant And then verify that the cable is connected properly Orange LED blinks after the Ethernet cable is connected Verify that the device at the other end of the Ethernet cable is working properly And...

Page 15: ...Hardware Installation and Reference Guide Troubleshooting 3 Adjust the transmit power 4 Move the client device to adjust the distance between the client and the AP...

Page 16: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...

Page 17: ...the bend radius should be 10 times the overall diameter The minimum bend radius of a high speed cable such as an SFP cable should be 5 times the overall diameter of the cable If the cable is constantl...

Page 18: ...ation is not affected and no damages occur to the device and cables during debugging Do not bind power cords to the rails for moving parts Leave a certain length of the cable connecting moving parts s...

Page 19: ...to fasten terminals Bundle cables of the same type and running in the same direction into groups Keep cables clean and straight Cables shall be tied according to the following table Diameter of Cable...

Reviews: