Ruijie RG-NBS3100 Series Switches Hardware Installation and Reference Guide
Product Overview
7
LED
Panel Identification
State
Meaning
(0.5Hz)
Ruijie Cloud.
Blinking green
(10Hz)
The switch is being upgraded or initialized.
Solid green
The switch is connected to Ruijie Cloud.
10/100/1000Base-T
Ethernet port status
LED
1-24
Off
The port is not connected.
Solid green
The port is connected at 10/100/1000 Mbps.
Blinking green
The port is receiving or transmitting traffic.
SFP port status LED
25-28
Off
The port is not connected.
Solid green
The port is connected at 100/1000 Mbps.
Blinking green
The port is receiving or transmitting traffic.
1.2 RG-NBS3100-24GT4SFP-P
Technical Specifications
Model
RG-NBS3100-24GT4SFP-P
CPU
Built-in CPU, single-core processor, 500MHz
Flash Memory
16 MB
SDRAM
DDRIII 256MB
Optical Module
See
Appendix B
.
The copper cable is not supported.
The supported module type may change at any time. Consult Ruijie Networks for the latest
information.
SFP Port
1000Base-X
100Base-X
Power Supply
AC input
Rated voltage range: 100V to 240V
Maximum voltage range: 90V to 264V
Frequency: 50/60 Hz
Rated current: 6A
Input
Leakage
Current
≤
3.5mA
EEE
Supported
PoE
Supports PoE and PoE+.
Ports 1-24 are PoE-capable with the maximum power output of 30W per port.
The overall maximum output power of PoE/PoE+ is 370W.
PoE Mode
Mode A (data pairs 1-2 and 3-6)
Power
Consumption
21W with no PoE load;
443W with PoE full load
Temperature
Operating temperature: 0 ºC to 50ºC
Storage temperature: -40 ºC to 70ºC
Humidity