Ruijie RG-NBS3100 Series Switches Hardware Installation and Reference Guide 

 

Troubleshooting 

 

31 

 

5    Troubleshooting 

5.1  General Troubleshooting Flowchart 

 

5.2  Troubleshooting Common Faults 

Symptom 

Possible Causes 

Solution 

Forgetting 

the 

management interface 

login password 

A password is manually configured but 

it is forgotten. 

Press  the  reset  button  to  restore  the  default 

settings. 

The  Status  LED  is  off 

after power-on. 

The power supply is not enabled, or the 

power cable is loosened. 

Check whether the power socket is normal. 

Check  whether  the  power  cable  is  correctly 

connected. 

The RJ45 port is not in 

connectivity  or  it  is 

erroneous 

in 

receiving/transmitting 

frames. 

The  connected  twisted  pair  cable  is 

faulty. 

The length of the cable exceeds 100 m. 

The port has special configuration that 

has no common working mode with the 

connected switch. 

Replace the twisted pair cable. 

Check that the port configuration has the common 

working mode with the connected switch. 

The  fiber  port  cannot 

be connected. 

The  Rx  and  Tx  ends  are  connected 

reversely. 

The interconnected optical module type 

does not match. 

The fiber type is not correct. 

The length of the optical fiber exceeds 

Switch the Rx and Tx ends of the optical fiber. 

Replace  the  optical  module  with  one  of  the 

matched type. 

Replace  the  optical  fiber  with  one  of  the 

appropriate type. 

Replace  the  optical  fiber  with  one  of  the 

Summary of Contents for RG-NBS3100 Series

Page 1: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...ite https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Suppo...

Page 4: ...wnward compatible with 100Base FX 1000Base T is downward compatible with 100Base TX and 10Base T 1 1 RG NBS3100 24GT4SFP Technical Specifications Model RG NBS3100 24GT4SFP CPU Built in CPU single core...

Page 5: ...61000 3 3 EN 55035 ETSI EN 300 386 Security Standards GB4943 2011 EN 62368 1 Dimensions W x D x H 440 mm x 165 mm x 44 mm Weight 2 4 kg The RG NBS3100 24GT4SFP switch is a class A product In a domest...

Page 6: ...the separate protective earthing terminal The device installation shall be permanently connected to building earth by a skilled person The device shall be intended to be used in a location having equ...

Page 7: ...cal Specifications Model RG NBS3100 24GT4SFP P CPU Built in CPU single core processor 500MHz Flash Memory 16 MB SDRAM DDRIII 256MB Optical Module See Appendix B The copper cable is not supported The s...

Page 8: ...RG NBS3100 24GT4SFP P switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures The high tempera...

Page 9: ...he LED is solid green it indicates that the PoE supported ports are supplying power when the LED blinks green the power of the ports is overloaded Back Panel Figure 1 6 Back Panel of RG NBS3100 24GT4S...

Page 10: ...f The port is not connected Solid green The port is connected at 10 100 1000 Mbps Blinking green The port is receiving or transmitting traffic at 10 100 1000 Mbps RJ45 port PoE status LED 1 24 Off PoE...

Page 11: ...d Power Consumption 8W Temperature Operating temperature 0 C to 50 C Storage temperature 40 C to 70 C Humidity Operating humidity 10 to 90 RH Storage humidity 5 to 95 RH Fan Not supported Temperature...

Page 12: ...00 8GT2SFP Front Panel Figure 1 9 Front Panel of RG NBS3100 8GT2SFP Note 1 System status LED 2 Reset button 3 10 100 1000 Base T Ethernet port 4 Copper port status LED 5 1000 Base X SFP port 6 SFP por...

Page 13: ...air circulation It is recommended to clean the device once every 3 months to avoid dust from blocking vents LED LED Panel Identification State Meaning System status LED Status Off The switch is not re...

Page 14: ...PoE Supports PoE and PoE Ports 1 8 are PoE capable with the maximum power output of 30W per port Port 9 does not support PoE The overall maximum output power of PoE PoE is 125W PoE Mode Mode A data pa...

Page 15: ...d be installed in the restricted area when the ambient temperature exceeds 50 deg C Product Appearance On the front panel the RG NBS3100 8GT2SFP P Ethernet switch provides 8 10 100 1000Base T Ethernet...

Page 16: ...a skilled person The device shall be intended to be used in a location having equipotential bonding such as a telecommunication centre a dedicated computer room or a restricted access area Heat Dissi...

Page 17: ...lation Keep the chassis clean and free from dust Do not place the equipment in a passage Do not wear loose clothes or any other things that may be caught by the chassis during installation and mainten...

Page 18: ...eakage protector divided by two is greater than the sum of maximum leakage currents of all the power supplies The rated leakage non action current of a leakage protector shall be 50 of the leakage act...

Page 19: ...the equipment may be damaged In an environment with high relative humidity the insulating material may have bad insulation or even leak electricity Sometimes the materials may suffer from mechanical...

Page 20: ...caused by capacity coupling inductance coupling electromagnetic wave radiation common impedance including grounding system coupling and conducting wires including power cords signal and output wires T...

Page 21: ...tection system of a facility is an independent system that consists of the lightning rod download conductor and the connector to the grounding system which usually shares the power reference ground an...

Page 22: ...er Radiated interference may affect any signal path in the equipment and is difficult to shield For the AC power supply system TN single phase three core power socket with protective earthing conducto...

Page 23: ...re installation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch Whether power ca...

Page 24: ...pted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment room and outdoor cabling of such cables is prohibited If outdoor cabling is necessar...

Page 25: ...Port Switch Figure 3 5 Attaching the Brackets to the Rack 24 Port Switch Figure 3 6 Attaching the Brackets to the Rack 24 Port Switch 3 3 2 Mounting the Switch on a Table Attach the four rubber pads...

Page 26: ...aximum current Cables of good conductor should be used Do not use bare wire The grounding electric resistance should be less than 1 To guarantee the security of the body and the device the switch must...

Page 27: ...fibers at the connectors have natural bends or bends of large radius Do not bundle fibers and twisted pairs too tightly as this may press hard the fibers and affect their service time and transmission...

Page 28: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide Product Installation 28 Check that sufficient airflow is available around the device over 10 cm...

Page 29: ...d RJ 45 port of the network cable to any Ethernet port of the switch Configuring the Device Step 1 Start the PC and configure the IP address of the PC as 10 44 77 XXX 10 44 77 XXX indicates the IP add...

Page 30: ...the parameters are already configured Checking after Power on Recommended After power on you are recommended to perform the following checks to ensure the normal operation of follow up configurations...

Page 31: ...port is not in connectivity or it is erroneous in receiving transmitting frames The connected twisted pair cable is faulty The length of the cable exceeds 100 m The port has special configuration tha...

Page 32: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide Troubleshooting 32 that rated of the optical module appropriate length...

Page 33: ...BASE T port uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schematic Diagram for...

Page 34: ...and Connection Media 34 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection s...

Page 35: ...ransmitted Light dBm Intensity of Received Light dBm Min Max Min Max MINI GBIC SX MM8 50 850 MMF No 9 5 3 17 0 MINI GBIC LX SM13 10 1310 SMF No 9 5 3 20 3 GE eSFP SX MM85 0 850 MMF Yes 9 5 3 17 0 GE e...

Page 36: ...MF 50 125 500m GE SFP SX SM1550 BIDI LC MMF 50 125 500m GE SFP LX20 SM1310 BIDI LC SMF 9 125 20km GE SFP LX20 SM1550 BIDI LC SMF 9 125 20km GE SFP LH40 SM1310 BIDI LC SMF 9 125 40km GE SFP LH40 SM1550...

Page 37: ...Module 37 Rate Distance Module Pairs 1000M 500m GE SFP SX SM1310 BIDI GE SFP SX SM1550 BIDI 1000M 20km GE SFP LX20 SM1310 BIDI GE SFP LX20 SM1550 BIDI 1000M 40km GE SFP LH40 SM1310 BIDI GE SFP LH40 SM...

Page 38: ...cal requirement Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester l...

Page 39: ...to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the framework According to the description on the Ethernet Port Arrester Hardware Instal...

Page 40: ...to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to con...

Page 41: ...erall diameter The minimum bend radius of a coaxial cable should be 7 times the overall diameter of the cable If the cable is constantly bent plugged or unplugged the bend radius should be 10 times th...

Page 42: ...proper cable ties to bind cables together Do not tie two or more cable ties to bind cables Cut off excess cable tie cleanly with no sharp edges after bundling cables as shown in Figure D 2 Figure D 2...

Page 43: ...ed and prevented from loosening as shown in Figure D 4 Figure D 4 Fastening Cable Lugs Note Flat washer Nut Spring washer Flat washer When using a stiff cable fix it near the cable lug to avoid stress...

Page 44: ...conditions such as windstorm and heavy rain as well as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the resid...

Page 45: ...Ruijie RG NBS3100 Series Switches Hardware Installation and Reference Guide 45...

Reviews: