RG-IS2700G Series Switch Hardware Installation and Reference Guide
refer to AppendixB for BIDI optic module details.
SFP Port
Supporting 1000Base-X;
Supporting 2.5Gbps bandwidth, and VSU deployment
Power Supply
AC input:
Rated voltage range: 100VAC to 240VAC
Maximum voltage range: 85VAC to 265VAC
Frequency: 50Hz to 60Hz
Rated current: 0.4A
HVDC input:
Rated voltage range: 140VDC to 340VDC
Maximum voltage range: 130VDC to 370VDC
Rated current: 0.4A
Power Consumption
Max.12 W
Operating Temperature
-40ºC to 85ºC
Storage Temperature
-40ºC to 85ºC
Operating Humidity
10% to 90% RH (non condensing)
Storage Humidity
10% to 90% RH (non condensing)
Fan
Fanless
Temperature Warning
Support
IP Rating
IP40
EMI
GB 9254-2008,FCC Part 15, CISPR (EN55022) class A,
EMS
IEC/EN 61000-4-2 ESD
Contact Discharge: 8 kV
Air Discharge: 15 kV
IEC/EN 61000-4-3 RS
80-1,000 MHz 10V/m
1,400-2,000 MHz 3V/m
2,000-2,700 MHz 1V/m
IEC/EN 61000-4-4 EFT
Power cable 2 kV