background image

Hardware Installation and Reference Guide 

 

Preparing for Installation 

 

 

2.2.2  Outdoor Installation   

RG-EST310 supports wall mounting and pole mounting. 

2.2.3  EMI 

Various interference sources, from either outside or inside the device or application system, affect the system in the 

conductive ways such as capacitive coupling, inductive coupling, and electromagnetic radiation. There are two types of 

electromagnetic interferences: radiated interference and conducted interference, depending on the type of the 

propagation path. When the energy, often RF energy, from a component arrives at a sensitive component via the space, 

the energy is known as radiated interference. The interference source can be either a part of the interfered system or a 

completely electrically isolated unit. Conducted interference results from the electromagnetic wire or signal cable 

connection between the source and the sensor. Interference along the cable the interference is transmitted from one unit 

to another. Conducted interference often affects the power supply of the device, but can be controlled by a filter. 

Radiated interference may affect any signal path in the device, and is difficult to shield. 

 

Effective measures should be taken for the power system to prevent electric grid interference.   

 

The working ground of the routers should be properly separated and kept as far as possible from the grounding 

device of the power device or the anti-lightning grounding device.   

 

Keep the device away from high-power radio transmitter, radar transmitting station, and high-frequency large-

current device. 

 

Take electrostatic shielding measures. 

2.3  Installation Tool 

Table 2-2 Installation Tools 

Tools 

Marker,  Phillips  (crosshead)  screwdriver,  slotted  screwdriver,  drill,  paper  knife, 

crimping pliers, diagonal pliers, wire stripper, network cable tester, related power and 

fiber cables, wrench, hammer, cable ties, ESD tools, multimeter 

 

The tool kit is not shipped with RG-EST310. You need to prepare a tool kit.   

2.4  Unpacking and Checking 

Please check your goods carefully against the parts list. If you have any questions or there are any errors, please contact 

your distributor.

Summary of Contents for RG-EST310 Series

Page 1: ...Ruijie RG EST310 Series Wireless Bridges Hardware Installation and Reference Guide 1 00...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes netwo...

Page 4: ...GHz 867Mbps Modulation OFDM BPSK 6 9Mbps QPSK 12 18Mbps 16 QAM 24Mbps 64 QAM 48 54Mbps OFDM BPSK QPSK 16QAM 64QAM 254QAM Receive Sensitivity 11a 89dBm 6Mbps 80dBm 24Mbps 76dBm 36Mbps 71dBm 54Mbps 11n...

Page 5: ...mera mode LAN Port Status Solid on The LAN port is not receiving or transmitting data Blinking The LAN port is receiving or transmitting data RSSI 3 LEDs in total LED 1 blinks RSSI 69dBm LED 1 is soli...

Page 6: ...Hardware Installation and Reference Guide Product Overview Figure 1 2 Bottom View of RG EST310 Ports Figure 1 3 Ports...

Page 7: ...ote 1 12 VDC Port 2 10 100Base T Ethernet Port PoE capable 3 Reset Power Supply RG EST310 adopts 24 V PoE or 12 VDC power supply standard accessory 24 V 0 5A PoE adapter Note Please do not use a PoE a...

Page 8: ...he antenna port and power port support 4kV lightning protection If a lightning protector of a higher profile is available configure the lightning protector optionally Before the configuration connect...

Page 9: ...ne unit to another Conducted interference often affects the power supply of the device but can be controlled by a filter Radiated interference may affect any signal path in the device and is difficult...

Page 10: ...ion site is equipped with a proper power supply Network cables are in place 3 3 Precautions The device can be mounted on a wall and a pole diameter 35 mm to 89 mm If the diameter of the pole is out of...

Page 11: ...ed with the device or use a PoE adapter with the same specification Before connecting the power cord make sure the power switch is in the OFF position Make sure the power supply is properly connected...

Page 12: ...le into the PoE port of the PoE injector and plug the other end into the LAN port of the device Connect the LAN port of the PoE injector to the server or camera Connect the PoE adapter to the DC port...

Page 13: ...Installation and Reference Guide Installing the Device Please install the rear cover for waterproof and dustproof purpose Please do not use a PoE adapter or switch of another model The device may be...

Page 14: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...

Page 15: ...B 1 RG EST310 Parts List No Item QTY Remark 1 RG EST310 Camera End 1 2 RG EST310 Video Recorder End 1 3 24V 0 6A Power Adaptor 2 4 Ruijie RG EST310 Series Wireless Bridges Hardware Installation Guide...