Ruijie RG-EG Series Routers Hardware Installation and Reference Guide 

Product Overview 

 

Interface 

Interface 

Description 

WAN 

1 WAN port, used to connect to the DSL/Cable modem for Internet access. 

LAN 

4 LAN ports, used to connect the computer to the switch. The LAN3 port can be 

used as a WAN port via the Web configuration.   

 

LED Indicator 

LED Indicator 

Description 

SYS 

Blinking green (0.5Hz): The device has started up, but is not connected to the 

Ruijie Cloud. 

Solid green: The device has started up, and is connected to the Ruijie Cloud. 

Blinking green (10Hz): The device is starting up/shutting down. 

Speed 

Solid green: the port is connected at 10/100/1000 Mbps. 

Off: the port is not connected at 10/100/1000 Mbps.   

 

Button 

Button 

Description 

Reset 

Press  reset  button  until  the  status  LED  blinks  green  at  10Hz  to  restore  the 

device to the factory default setting. 

The default management IP address is http://192.168.110.1. 

 

1.4  RG-EG210G-P 

Specifications 

Model 

RG-EG210G-P 

Storage 

DDR3 SDRAM: 256MB 

ROM: 16MB 

Power Module 

External 80W power adapter 

Interface Standard 

Ethernet: 10Base-T/100Base-TX/1000Base-TX 

Dimension  (without 

rubber pads) 

(W x H x D) 

202 mm x 28 mm x 108 mm (7.95 in. x 1.1 in. x 4.25 in.)   

Voltage 

100V to 240V~, 50/60Hz, 1.5A max. 

Power Consumption   

Less than 80W (With PoE) 

PoE 

IEEE 802.3af/at, 70W max. output 

Working 

Temperature 

0°C to 40°C (32°F to 104°F) 

Summary of Contents for RG-EG Series

Page 1: ...Ruijie RG EG Series Routers Hardware Installation and Reference Guide ...

Page 2: ... or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any notice Please obtain the latest information through the Ruijie Networks website Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages cau...

Page 3: ...site https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes network protocols and related mechanisms that supporte...

Page 4: ...Model RG EG105G P Storage DDR2 SDRAM 128MB ROM 16MB Power Module External 60W power adapter Interface Standard Ethernet 10Base T 100Base TX 1000Base TX Dimension without rubber pads W x H x D 206 5 mm x 28 mm x 108 5 mm 8 13 in x 1 1 in x 4 27 in Voltage 100V to 240V 50 60Hz 1 5A max Power Consumption Less than 60W With PoE PoE IEEE 802 3af at 54W max output Working Temperature 0 C to 40 C 32 F to...

Page 5: ...as started up and is connected to the Ruijie Cloud Blinking green 10Hz The device is starting up shutting down or PoE overload occurs Link ACT Solid green the port is up Blinking green data is being transceived on the port Button Button Description Reset Press reset button until the status LED blinks green at 10Hz to restore the device to the factory default setting The default management IP addre...

Page 6: ...ible measures against such interference Appearance Figure 1 3 Front Panel of RG EG105G Figure 1 4 Back Panel of RG EG105G Interface Interface Description WAN 1 WAN port used to connect to the DSL Cable modem for Internet access LAN 4 LAN ports used to connect the computer to the switch The LAN3 port can be used as a WAN port via the Web configuration LED Indicator LED Indicator Description Status ...

Page 7: ... 802 11b g n 2 4GHz to 2 483GHz 802 11a n ac 5 15GHz to 5 35GHz 5 47GHz to 5 725GHz 5 725GHz to 5 85GHz Country Specific Max Throughput 2 4G up to 450Mbps 5G up to 867Mbps Up to 1 317Gbps per device Transmit Power 27dBm 2 4G 25dBm 5G Country Specific Dimension without rubber pads W x H x D 250 mm x 42 mm x 174 mm 9 84 in x 1 65 in x 6 85 in Voltage 100V to 240V 50 60Hz 0 6A max Power Consumption L...

Page 8: ...Ruijie RG EG Series Routers Hardware Installation and Reference Guide Product Overview Figure 1 5 Front Panel of RG EG105GW Figure 1 6 Back Panel of RG EG105GW ...

Page 9: ...ing up shutting down Speed Solid green the port is connected at 10 100 1000 Mbps Off the port is not connected at 10 100 1000 Mbps Button Button Description Reset Press reset button until the status LED blinks green at 10Hz to restore the device to the factory default setting The default management IP address is http 192 168 110 1 1 4 RG EG210G P Specifications Model RG EG210G P Storage DDR3 SDRAM...

Page 10: ...ure 1 8 Back Panel of RG EG210G P Interface Interface Description WAN 1 WAN port used to connect to the DSL Cable modem for Internet access LAN 9 LAN ports used to connect the computer to the switch or access point AP The LAN8 port can be used as a WAN port via the Web configuration LED Indicator LED Indicator Description Status Blinking green 0 5Hz The device has started up but is not connected t...

Page 11: ...rdware Installation and Reference Guide Product Overview Reset Press reset button until the status LED blinks green at 10Hz to restore the device to the factory default setting The default management IP address is http 192 168 110 1 ...

Page 12: ...ace the battery by yourself Please contact the technical support for help Install and use the device in restricted access locations Invite professionals and related technicians to install this type of device Where a plug on the power supply cord is used as the disconnect device the installation instructions shall state that for pluggable equipment the socket outlet shall be easily accessible For p...

Page 13: ...ntained in the air These noxious gases will accelerate metal wastage and the aging of certain parts The upper limits of noxious gases Sulfur dioxide Sulfured hydrogen Nitrogen dioxide Ammonia and Chlorine in the following table Gas Average mg m 3 Maximum mg m 3 SO2 0 2 1 5 HS 0 0 03 NO2 0 04 0 15 N2 0 05 0 15 Cl2 0 01 0 3 2 2 3 ESD The router has already given consideration to electrostatic preven...

Page 14: ...stalled in the cabinet or on the workbench the following requirements shall be met Make sure sufficient room has been reserved for the air intake and air vent of router to facilitate the heat elimination of the router chassis It is recommended to install the router in the 19 inch standard cabinet Otherwise install it on a clean and flat surface In heated areas the air conditioning system shall be ...

Page 15: ...ng the router refers to installing the device to the specified position Upon completion of installation preparation fix the router to the specified position The installation position of router is generally a cabinet or a workbench Mounting on a Workbench In most cases the user does not have a standard cabinet Instead the user can place the device on a clean workbench Although it is easy and simple...

Page 16: ...unded during the construction You need to make sure the power supply is properly grounded Please take the following steps Plug one end of the power cable into the power socket on the backpanel of the router and plug the other end into the AC power supply outlet Check whether the power LED on the front panel of the router lights up or not The LED indicator will light up if the power supply is prope...

Page 17: ... ground wire are properly connected Whether the power voltage is consistent with the requirement of the router Whether the configuration cable is properly connected and whether the microcomputer or terminal for device configuration is started or configured Before powering on the router be aware of the location of the power switch of the router to timely cut off power supply in case of any accident...

Page 18: ...Installation and Reference Guide Quick Configuration 4 3 Configuring Router To use the router you need to properly configure the router as required Refer to the relevant Web based configuration guide for details about router configuration ...

Page 19: ...ed Whether the power supply to the router meets relevant requirements Do not plug or pull the power cable when the device is powered on If everything is ok but the Status LED still does not light up contact with a local distributor or technical support personnel 5 2 Configuration System After the router is powered on the Web based configuration system is available if the device works normally If n...

Reviews: