Ruijie Reyee RG-RAP6260 Hardware  Installation And Reference Manual Download Page 26

·

 

 

 

 

 

Note 

1. Flat washer 

2. Nut 

3. Spring washer 

4. Flat washer 

 

When using a stiff cable, fix it near the cable lug to avoid stress on the lug and cable.       

 

Do not use self-tapping screws to fasten terminals.   

 

Bundle cables of the same type and running in the same direction into groups. Keep cables clean and straight.     

 

Cables shall be tied according to the following table.   

Diameter of Cable Bundle (mm) 

Space between Bundles (mm) 

10 

80 to 150 

10 to 30 

150 to 200 

30 

200 to 300 

 

Do not tie knots for cables or cable bundles.   

 

The metal parts of the cold-pressed terminal blocks, such as air circuit breakers, shall not be exposed outside of the 

blocks. 

 

Summary of Contents for Reyee RG-RAP6260

Page 1: ...Ruijie Reyee RG RAP6260 G Access Point Hardware Installation and Reference Guide...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Page 4: ...50 GHz 5 725 GHz to 5 850 GHz Antenna Antenna array 2 4G 4dBi 5G 6dBi Spatial Streams 2 4G 2x2MIMO 5G 2x2MIMO Access Rates 2 4GHz up to 575Mbps 5GHz up to 1200Mbps Modulation OFDM BPSK 6 9Mbps QPSK 12...

Page 5: ...e 0 to 100 non condensing condensing Installation Wall Pole mount Safety Standards GB4943 IEC 60950 1 EMC Standards GB9254 EN301 489 EN50155 EN50121 Vibration Standards IEC61373 Radio China Radio Tran...

Page 6: ...nking 0 5Hz Normal operation but the device is not connected to Ruijie Cloud Fast Blinking 10Hz 1 Restoring the factory settings 2 Upgrading the firmware 3 Restoring the image file 4 Initializing the...

Page 7: ...oud If the device can not access the Internet power on the device press the reset button with a thin rod as shown in the figure for more than 5 seconds and the device will restore the factory settings...

Page 8: ...ble voltage vibration and noises Keep the AP at least 500 meters away from the seaside and do not face it toward the wind from the sea The installation site should be free from water flooding seepage...

Page 9: ...latively high humidity may affect insulation materials resulting in poor insulation and even electrical leakage and sometimes may lead to change of mechanical properties of materials and corrosion of...

Page 10: ...re customer supplied 2 9 Unpacking the Access Point Package Contents Items Verify that all parts are installed and debugged Screws Mounting brackets Product quick installation guide Packing list The a...

Page 11: ...You Begin Before you install the AP verify that The installation site provides sufficient ventilation for the AP The installation site meets temperature and humidity requirements The installation site...

Page 12: ...llation Install the device in a well ventilated location Do not subject the device to high temperatures Keep away from high voltage cables Do not expose the device in a thunderstorm or strong electric...

Page 13: ...expansion bolts Figure 3 2 Installing the Bracket b Align the host with bracket and mounting plate to the bracket on the wall and tighten the M8x20 screws to complete installation Figure 3 3 Mounting...

Page 14: ...ertical Pole Mounting Pole mount Horizontal a Attach the bracket to a pole with hose clamps and fasten the clamps with screws and nuts Figure 3 6 Mounting the Bracket on a Pole b Align the host with b...

Page 15: ...n shown in Note 1 The device uses high gain omnidirectional antenna It is recommended to set the joint downward to be perpendicular to the ground to obtain the maximum coverage radius After installati...

Page 16: ...icker or thinner cable does not ensure waterproof performance When the joint is removed take down the parts in the order of D B C and A That is first screw off the tightening nut D then remove the rub...

Page 17: ...Make sure the UTP STP cable matches the interface type Make sure cables are properly bundled Checking the Power Supply Make sure all power cables are properly connected and safe Make sure the AP is o...

Page 18: ...C for debugging verify that the PC and PoE switch are properly grounded 4 2 Powering up the AP Checking before power up Verify that the power supply is properly connected Verify that the input voltage...

Page 19: ...toring and Maintenance 5 1 Monitoring LED You can observe the LED to monitor the AP in operation 5 2 Hardware Maintenance If the hardware is faulty please contact our Technical Assistance Center TAC f...

Page 20: ...ble is connected properly Ethernet port is not working after the Ethernet port is connected Verify that the device at the other end of the Ethernet cable is working properly And then verify that the E...

Page 21: ...3 Verify that the AP is configured correctly 4 Move the client device to adjust the distance between the client and the AP...

Page 22: ...1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5 100 ohm UTP STP and 1000BASE T uses...

Page 23: ...LX MM 1310 1310 MMF1 62 5 125 2 km 14 14 IEEE802 3 FE SFP LH15 S M1310 1310 SMF2 9 125 15 km 8 8 MINI GBIC SX MM850 850 MMF1 62 5 62 5 50 0 50 0 160 200 400 500 220 m 275 m 500 m 550 m 4 17 MINI GBIC...

Page 24: ...overall diameter The minimum bend radius of a high speed cable such as an SFP cable should be 5 times the overall diameter of the cable If the cable is constantly bent plugged or unplugged the bend ra...

Page 25: ...ccur to the device and cables during debugging Do not bind power cords to the rails for moving parts Leave a certain length of the cable connecting moving parts such as the ground wire of the cabinet...

Page 26: ...he same type and running in the same direction into groups Keep cables clean and straight Cables shall be tied according to the following table Diameter of Cable Bundle mm Space between Bundles mm 10...

Reviews: