2. Run a network cable or fiber (optional) through the joint according to the order shown in the figure, and combine parts
B and C and place them in part A.
3. Screw part D, and wear the joint tightly with a waterproof tape.
Figure 3-9 Cable Connection
The waterproof materials are customer supplied.
Avoid bending the cable in a small radius close to the connector.
It is not recommended to use Ethernet cables with protective sleeves as they could make installation of Ethernet
cables more difficult. The Ethernet cable must have a diameter of 5.5
1mm, because any thicker or thinner cable
does not ensure waterproof performance.
As an optical module (optional) is enabled, the LC-LC fiber jumper cable must have a diameter of 3.0
0.2mm,
because any thicker or thinner cable does not ensure waterproof performance.
When the joint is removed, take down the parts in the order of D, B, C and A. That is, first screw off the tightening nut
(D), then remove the rubber plug (B) and the grab (C), and finally dismantle the cable connected to the AP device;
otherwise, the cable will be damaged.
3.6 Bundling Cables
Precautions
Make sure the cable bundles are neat and orderly.
Bend twisted pairs naturally or to a large radius close to the connector.
Do not over tighten cable bundle as it may reduce the cable life and performance.
Bundling Steps
1. Bundle the drop UTP/STP cables and route them to the ETH/PoE port.
2.
Attach the cables in the cable tray of the rack.
3.
Extend the cables under the AP and run in straight line.
3.7 Checking after Installation
Checking the Host
Make sure the external power supply matches the specifications of device.
Make sure the device and all cables are securely fastened and stable.