Hardware Installation and Reference Guide Preparation before Installation
prevent the current of high-voltage lightning from passing the switch directly through the mains supply cable to a certain
extent.
The lightning line banks are not provided and should be purchased by users as required.
For the usage of lightning line banks, refer to their related manuals.
2.2.7 EMI Consideration
Electro-Magnetic Interference (EMI), from either outside or inside the equipment or application system, affects the system
in the conductive ways such as capacitive coupling, inductive coupling, and electromagnetic radiation.
There are two types of electromagnetic interferences: radiated interference and conducted interference, depending on the
type of the transmission path.
When the energy, often RF energy, from a component arrives at a sensitive component via the space, the energy is
known as radiated interference. The interference source can be either a part of the interfered system or a completely
electrically isolated unit. Conducted interference results from the electromagnetic wire or signal cable connection between
the source and the sensitive component, along which cable the interference conducts from one unit to another. Conducted
interference often affects the power supply of the equipment, but can be controlled by a filter. Radiated interference may
affect any signal path in the equipment and is difficult to shield.
Effective measures should be taken for the power system to prevent the interference from the electric grid.
The grounding device of the switch must not be used as the grounding device of the electrical equipment or
anti-lightning grounding device. In addition, the grounding device of the switch must be deployed far away from the
grounding device of the electrical equipment and anti-lightning grounding device.
Keep the equipment away from high-power radio transmitter, radar transmitting station, and high-frequency
large-current device.
Measures must be taken to shield static electricity.
2.3 Requirements of Installation Tools
Table 2-4 List of Installation Tools
Common tools
Philipsscrewdriver, flathead screwdriver, related electric cables and optical cables, bolts, diagonal
pliers, straps
Special tools
Anti-static tools
Meters
Multimeter
The tool kit is customer supplied.