There are 0.5/3/10m power sharing cables for your choice. Use one power sharing cable to connect two
S2910-24GT4XS-PS-E switches. If the local power supply of Switch A is disconnected but that of Switch B remains
connected, Switch B provides 12V DC voltage to Switch A via the power sharing cable. In this way, Switch A is able
to continue its operation. Power sharing is also supported among three S2910-24GT4XS-PS-E switches. If the local
power supply of one or two switches is disconnected, none of the three switches are affected.
Heat Dissipation
The RG-S2910-24GT4XS-PS-E adopts turbine fans for heat dissipation, thereby ensuring normal function of the device in
the specified environment. 10 cm distance space should be reserved at both sides and the back plane of the cabinet to
allow air circulation. It is recommended to clean the device once every 3 months to avoid dust from blocking vents. Figure
1-24shows the flow scheme of heat dissipation.
Figure 1-24 Flow Scheme of Heat Dissipation
LEDs
LED
Panel Identification
State
Meaning
System status LED
Status
Off
The switch is not receiving power.
Blinking green
The system is being initialized.
Continuous blinking indicates errors.
Solid green
The switch is operational.