background image

 

 

 

 

 

 

 

RG-S2910XS-E Series Switch 

Hardware Installation and Reference Guide V1.14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for RG-S2910-24GT4XS-E

Page 1: ...RG S2910XS E Series Switch Hardware Installation and Reference Guide V1 14...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...site https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal http caseportal ruijienetworks com Community http community ruijienetworks com Technical Suppor...

Page 4: ...Port USB Port Expansion Module Slot Pluggable Power Slot RG S2910 24GT4XS E 24 4 1 1 N A N A N A RG S2910 48GT4XS E 48 4 1 1 N A N A N A RG S2910C 24GT2XS P E 24 PoE 2 2 Combo 1 N A 1 N A RG S2910C 2...

Page 5: ...re Warning Supported EMCStandards GB9254 2008 Security Standards GB4943 2011 Dimensions W x D x H 443mm x 268mm x 44 5mm Weight 3 5kg The RG S2910 24GT4XS E switch is a class A product In a domestic e...

Page 6: ...4XS E Note 1 System status LED 2 Console port 3 10 100 1000 Base T auto sensing Ethernet port 4 10G SFP port 5 10G SFP port 6 10 100 1000 Base T copper port status LED 7 SFP fiber port status LED Back...

Page 7: ...V to 290V Current range 0 1A to 0 5A Heat Dissipation The RG S2910 24GT4XS E full gigabit switch is designed with fans To ensure good dissipation sufficient space 10 cm distance from both sides and th...

Page 8: ...s connected at 10 100 Mbps Blinking Data are being transceived at the port SFP fiber port status LED 25F 28F Off The port is not connected Solid green The port is connected Blinking Data are being tra...

Page 9: ...ed EMCStandards GB9254 2008 Security Standards GB4943 2011 Dimensions W x D x H 443mm x 268mm x 44 5mm Weight 4kg The RG S2910 48GT4XS E switch is a class A product In a domestic environment this prod...

Page 10: ...8GT4XS E Note 1 System status LED 2 Console port 3 10 100 1000 Base T auto sensing Ethernet port 4 10G SFP port 5 10G SFP port 6 10 100 1000 Base T copper port status LED 7 SFP port status LED Back Pa...

Page 11: ...o 290V Current range 0 5A to 0 8A Heat Dissipation The RG S2910 48GT4XS E full gigabit switch is designed with fans To ensure good dissipation sufficient space 10 cm distance from both sides and the b...

Page 12: ...Data are being transceived at the port 1 3 RG S2910C 24GT2XS P E Technical Specifications Model RG S2910C 24GT2XS P E CPU Single core CPU with the clock speed of 1 0G BOOTROM Flash Memory 512MB SDRAM...

Page 13: ...justment and fault alarm Temperature Warning Supported EMC Standards GB9254 2008 Security Standards GB4943 2011 Dimensions W x D x H 440mm x 260mm x 44mm Weight 5 8kg with package The RG S2910C 24GT2X...

Page 14: ...g Ethernet port 9 100 1000Base X SFP port 10 SFP port Long press PoE Mode Switch Over Button for above 2 seconds to switch the display mode between PoE mode and port rate mode Back Panel Figure 1 11 B...

Page 15: ...nce space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is recommended to clean the device once every 3 months to avoid dust from blocking vents Figure...

Page 16: ...port status LED 1 24 Off The port is not connected Solid green The port is connected at 1000 Mbps Blinking green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is co...

Page 17: ...Flash Memory 512MB SDRAM DDRIII 512MB Optical Module See Appendix B The supported module type may change at any time Consult us for the latest information Expansion Module Supports M2910 01XT and M29...

Page 18: ...torage Humidity 5 to 95 RH Fan Speed adjustment and fault alarm Temperature Warning Supported EMCStandards GB9254 2008 Security Standards GB4943 2011 Dimensions W x D x H 440mm x 320mm x 44mm The dept...

Page 19: ...PoE status LED 6 Copper port status LED 7 Fiber port status LED 8 PoE mode switch over button 9 Console port 10 USB port 11 10 100 1000Base T auto sensing Ethernet port 12 100 1000Base X SFP port 13 S...

Page 20: ...g tables Model RG M5000E AC500P RG M5000E AC500P HVDC Platform RG S2910C 24GT2XS HP E RG S2910C 48GT2XS HP E RG S2910C 24GT2XS HP E RG S2910C 48GT2XS HP E Rated Voltage Range 100V to 240V 50 60 Hz 240...

Page 21: ...es 195 4 mm x 90 mm x 40 mm without connecting fingers or handles Weight 1 6kg Model RG M5000E DC500P Platform RG S2910C 24GT2XS HP E RG S2910C 48GT2XS HP E Rated Voltage Range 72V to 36V PoE Power Si...

Page 22: ...1 6kg Model RG PA1150P F RG PA1150P F HVDC Platform RG S2910C 24GT2XS HP E RG S2910C 48GT2XS HP E RG S2910C 24GT2XS HP E RG S2910C 48GT2XS HP E Rated Voltage Range 100V to 240V 50 60 Hz 240V Maximum...

Page 23: ...d state When the switch is powered by the dual power modules if the system working power is greater than the capacity of single power module power redundancy cannot work Heat Dissipation The RG S2910C...

Page 24: ...is being initialized Continuous blinking indicates errors Solid green The switch is operational Solid yellow Temperature warning Check the working environment of the switch immediately Solid red The s...

Page 25: ...Blinking green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connected at 10 100 Mbps Blinking yellow The port is receiving or transmitting traffic at 10 100 Mbp...

Page 26: ...ndix B The supported module type may change at any time Consult us for the latest information Expansion Module Supports M2910 01XT and M2910 01XS modules SFP Port Supports 100Base X and 1000Base X SFP...

Page 27: ...Humidity 5 to 95 RH Fan Speed adjustment and fault alarm Temperature Warning Supported EMCStandards GB9254 2008 Security Standards GB4943 2011 Dimensions W x D x H 440mm x 360mm x 44mm The depth is 46...

Page 28: ...LED 5 Power module 2 status LED 6 PoE status LED 7 Copper port status LED 8 Fiber port status LED 9 PoE mode switch over button 10 Console port 11 USB port 12 10 100 1000Base T auto sensing Ethernet p...

Page 29: ...switch is powered in the load balanced mode When the switch is powered by the dual power modules if the system working power is greater than the capacity of single power module the power redundancy c...

Page 30: ...he switch is not receiving power Blinking green The system is being initialized Continuous blinking indicates errors Solid green The switch is operational Solid yellow Temperature warning Check the wo...

Page 31: ...t status LED 1 24 Off The port is not connected Solid green The port is connected at 1000 Mbps Blinking green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connec...

Page 32: ...B Optical Module See Appendix B The supported module type may change at any time Consult us for the latest information SFP Port Supports 10Gbase R and 1000Base X SFP modules Power Supply AC input Rate...

Page 33: ...o interference in which case the user may be required to take adequate measures Product Appearance On the front panel the RG S2910 24GT4XS PS E Ethernet switch provides 1 Console port 24 10 100 1000Ba...

Page 34: ...n reboot the device Back Panel Figure 1 23 Back Panel of RG S2910 24GT4XS PS E Note 1 Grounding pole 2 Power cord retention clips 3 PowerShare port 1 4 PowerShare port 2 5 3 pin AC power port 6 Heat d...

Page 35: ...ches are affected Heat Dissipation The RG S2910 24GT4XS PS E adopts turbine fans for heat dissipation thereby ensuring normal function of the device in the specified environment 10 cm distance space s...

Page 36: ...rt is receiving or transmitting traffic at 10 100 Mbps SFP port status LED 25F 28F Off The port is not connected Solid green The port is connected Blinking green The port is receiving or transmitting...

Page 37: ...t 10G copper module 1 10GBASE T auto sensing Ethernet port M2910 01XS 1 port SFP module 1 SFP port M2910 02XS 2 port SFP module 2 SFP ports For the detailed information about the supported modules ple...

Page 38: ...ve local regulations and specifications when performing electric operations Relevant operators must be qualified Before installing the device carefully check any potential danger in the surroundings s...

Page 39: ...he leakage current is below 15mA the protector shall not act Otherwise misoperation may easily occur due to high sensitivity and thus the leakage protector trips devices are powered off and services a...

Page 40: ...lic parts may get rusted In an environment with low relative humidity however the insulating strip may dry and shrink Static electricity may occur easily and endanger the circuit on the equipment In a...

Page 41: ...o the grounding requirements and perform grounding operations properly as required Effective grounding of the switch is an important guarantee for lightning protection and interference resistance Ther...

Page 42: ...s supply cable to a certain extent The lightning line banks are not provided and should be purchased by users as required For the usage of lightning line banks refer to their related manuals 2 2 6 EMI...

Page 43: ...ing station and high frequency large current device Measures must be taken to shield static electricity Interface cables should be laid inside the equipment room Outdoor cabling is prohibited avoiding...

Page 44: ...ation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch Whether power cables are a...

Page 45: ...quency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment roo...

Page 46: ...e 3 3 Figure 3 3 3 3 2 Mounting the Switch on the Wall The RG 2910XS E series switch can be mounted on the wall as shown in the following figure Attach the mounting brackets to the switch with the sup...

Page 47: ...e wall as shown in Figure 3 5 Figure 3 4 Attaching the Switch on the Wall 3 3 3 Mounting the Switch on a Table Attach the four rubber feet to the recessed areas on the bottom of the switch as shown in...

Page 48: ...nnecting Power Sharing Cables The S2910 24GT4XS PS E switch supports power sharing among up to 3 devices The cable connecting steps are as follows Step 1 Remove the dust cap on the Powershare ports to...

Page 49: ...by three switches you need three power sharing cables Firstly insert one end of the first cable into a port on Switch A and insert the other end of the cable into a port on Switch B Then insert one e...

Page 50: ...personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected Check that all interfa...

Page 51: ...port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the switch Setting HeperTerminal Parameters Step 1 Start the PC and run the terminal simulation program on t...

Page 52: ...layed Choose the serial port used currently in the column use when connecting Figure 4 3 4 After choosing the serial port click OK to display the serial port parameter setting interface set the baud r...

Page 53: ...onsole port of the switch The HyperTerminal is started and the parameter settings are correct 4 2 2 Checking after Program Startup Recommended After power on you are recommended to perform the followi...

Page 54: ...Check whether the service interface forwards data normally...

Page 55: ...upply power The power cable is in loose contact Check whether the power socket at the equipment room is normal and whether the power cable of the switch is in good contact The status indicator is red...

Page 56: ...n that has no common working mode with the connected switch Replace the twisted pair cable Check that the port configuration has the common working mode with the connected switch The fiber port cannot...

Page 57: ...n all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE T In addition to the above cables the 1...

Page 58: ...or the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4...

Page 59: ...62 5 125 2km Yes 22 14 30 14 FE SFP LH15 SM1310 1310 SMF 9 125 15km Yes 15 8 28 8 Table B 2 Models and Technical Specifications of the 1000M Mini GBIC Module Model Wave Length nm Media Type Core Size...

Page 60: ...FP Type 1000Base T Mini GBIC GT The existing 1000Base T module 1000baseT Copper Type Cabling Distance DDM Yes No Mini GBIC GT Category 5 or above UTP STP 100m No Table B 5 Models and Technical Specifi...

Page 61: ...G SFP CU1M Passive SFP 1 28 10 3125 No XG SFP CU3M Passive SFP 3 28 10 3125 No XG SFP CU5M Passive SFP 5 26 10 3125 No For the optical module with transmission distance exceeding 40 km and more one on...

Page 62: ...hat the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester lightning protection cable row lightning protection funct...

Page 63: ...s in good contact with the switch grounding terminal and the framework 4 According to the description on the Ethernet Port Arrester Hardware Installation Guide connect the arrester using the adapter c...

Page 64: ...e grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to confirm the contact condition after the grounding Incomple...

Page 65: ...ater than seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The bend radius of this type of cables that often bend or suf...

Page 66: ...traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables It is forbidden to connect two or more buckles to bund...

Page 67: ...guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled When the moving part reaches the installation pos...

Page 68: ...bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Diameter mm Binding Space mm 10 80 150 10 30 150 200 30 200 300...

Page 69: ...l as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet...

Reviews: