Back Panel
Figure 1-14 Back Panel of the RG-S2628G-P V2.XX Switch
Note:
1. Grounding pole
2. Fan outlet
3. 3-core AC power interface
4. Cable plug retention clip
Power Supply System
The RG-S2628G-P
can be powered either with AC power or DC power
.
AC
input:
Rated voltage range: 100–240 VAC
Maximum voltage range: 90–264 VAC
Frequency: 50/60 Hz
Rated current: 6 A
Power cable requirement: 10 A power cable
HVDC
input:
Maximum voltage range: 192 V to 290 V
Rated current: 3.5 A to 2.5 A
Power cord: 10A power cable
Heat Dissipation System
The RG-S2628G-P V2.XX adopts turbine fans for heat dissipation purposes, thereby ensuring the device to function
normally in the specified environment. Sufficient space (10 cm distance from both sides and the back panel of the cabinet)
should be reserved to allow air circulation. Dust the device every three months to avoid blocking the ventilation openings.
Figure 1-15 Flow Scheme of Heat Dissipation