RG-S2600E Series Switch 

Hardware Installation and Reference Guide V1.31

 

Summary of Contents for RG-S2628G-E

Page 1: ...RG S2600E Series Switch Hardware Installation and Reference Guide V1 31...

Page 2: ...n consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption Statement This document is provided as is The contents of this docu...

Page 3: ...bsite http www ruijienetworks com Online customer services http webchat ruijie com cn Customer service center http www ruijie com cn service aspx Customer services hotline 86 4008 111 000 BBS http sup...

Page 4: ...Port 10 100 1000Base T Ethernet Port 1000Base X SFP Port Console Port Extension Module Slot RG S2628G E 24 2 2 1 1 RG S2652G E 48 2 2 1 1 RG S2628G P V1 XX 24 2 2 1 1 RG S2628G P V2 XX 24 None 4 1 Non...

Page 5: ...0 RH Fan Fanless Temperature Warning Support EMC Standards GB9254 2008 Class A Safety Standards GB4943 2001 Dimensions W x H x D 440 mm x 44 mm x 260 mm Weight With extension modules 4 4 kg Without ex...

Page 6: ...11 100 1000Base X SFP port indicator Back Panel Figure 1 3 Back Panel of the RG S2628G E Switch Note 1 Grounding pole 2 3 core AC power interface 3 Cable plug retention clip 4 Extension module slot Po...

Page 7: ...n The port is transmitting or receiving data at 1000Mbps Solid yellow The port is connected at 100 10Mbps Extension module port indicator for the M3000E 02SFP GT Blinking yellow The port is transmitti...

Page 8: ...C GT The supported module type may change at any time For the detailed change information consult Ruijie Networks Extension Module Type M3000E 02SFP GT M3000E STACK SFP Port 100Base X 1000Base X RPS T...

Page 9: ...AC power input ports and one extension module slot Figure 1 4 Appearance of the RG S2652G E Switch Front Panel Figure 1 5 Front Panel of the RG S2652G E Switch Note 1 Switch status indicator 2 Extens...

Page 10: ...2 A The power cable requirement 10 A power cable Heat Dissipation System The RG S2652G E adopts turbine fans for heat dissipation purposes thereby ensuring the device to function normally in the spec...

Page 11: ...he stack port is connected Extension module port indicator For the M3000E STACK A B Blinking green The stack port is transmitting or receiving data Off The port is NOT connected Solid green The port i...

Page 12: ...d the whole device supports a maximum PoE output power of 370W the maximum output power of its single port is 15 4W and it supports PoE power supply for a maximum of 24 ports Max Power Consumption The...

Page 13: ...rance The front panel of the RG S2628G P switch provides twenty four 10 100Base T Ethernet ports two gigabit SFP fiber optic copper combo ports and one console port The back panel provides AC power in...

Page 14: ...tage range 100 240 VAC Maximum voltage range 90 264 VAC Frequency 50 60 Hz Rated current 6 A Power cable requirement 10 A power cable Redundant power input The switch power can be supplied by the redu...

Page 15: ...cables in the standard Ethernet interface for power supply instead of using isolation transformer in the data pair cables Therefore the standard network cables of Cat5 or better must be used in the a...

Page 16: ...The port is NOT connected Solid green The port is connected at 100Mbps Blinking green The port is transmitting or receiving data at 100Mbps Solid yellow The port is connected at 10Mbps 10 100Mbps RJ...

Page 17: ...se X RPS Type Not supported Power Supply AC input Rated voltage range 100 240 VAC Maximum voltage range 90 264 VAC Frequency 50 60 Hz Rated current 6 A HVDC input Maximum voltage range 192 to 290 VDC...

Page 18: ...anel provides the AC power input port Figure 1 12 Appearance of the RG S2628G P V2 XX Switch Front Panel Figure 1 13 Front Panel of the RG S2628G P Switch Note 1 PoE switching mode indicator 2 Switch...

Page 19: ...able requirement 10 A power cable HVDC input Maximum voltage range 192 V to 290 V Rated current 3 5 A to 2 5 A Power cord 10A power cable Heat Dissipation System The RG S2628G P V2 XX adopts turbine f...

Page 20: ...ur wire cables may lead to failure of powering to PD LED Indicators Indicator Panel Identification Status Meaning Solid green The port indicator indicates the switching status PoE switching mode indic...

Page 21: ...FE SFP LX MM1310 FE SFP LH15 SM1310 Mini GBIC SX Mini GBIC LX Mini GBIC LH40 Mini GBIC ZX50 Mini GBIC ZX80 Mini GBIC ZX100 Mini GBIC GT The supported module type may change at any time For the detail...

Page 22: ...e 40 C to 70 C Humidity Working humidity 10 to 90 RH Storage humidity 5 to 90 RH Fan Supports adjustment of fan speed and warning of fan troubles Temperature Warning Support EMC Standards GB9254 2008...

Page 23: ...0Base T adaptive Ethernet port indicator 14 100 1000Base X SFP port indicator Back Panel Figure 1 18 Back Panel of the RG S2652G P Switch Note 1 Grounding pole 2 RPS input interface 3 3 core AC power...

Page 24: ...e back panel of the cabinet to allow air circulation Dust the device every three months to avoid blocking the ventilation openings Figure 1 19 Flow Scheme of Heat Dissipation Powering Cabling for PD P...

Page 25: ...Off The port is NOT connected Solid green The port is connected at 100Mbps Blinking green The port is transmitting or receiving data at 100Mbps Solid yellow The port is connected at 10Mbps 10 100Mbps...

Page 26: ...Base T adaptive Ethernet port form a fiber optic copper combo port That is only one port in the fiber optic copper combo port is available at a particular time Mappings between Two Ports that Form a F...

Page 27: ...and feet or straining the back Before moving the device turn off all power supplies and dismantle all power modules Electric Safety Observe local regulations and specifications when performing electri...

Page 28: ...eyes Installation Site Requirements The RG S2600E series must be used indoors To ensure the normal working and a prolonged durable life of the equipment the installation site must meet the following r...

Page 29: ...when there is no protective plate in front or back of the equipment rack Cleanness Requirements Dust poses a severe threat to the running of the equipment The indoor dust falling on the equipment may...

Page 30: ...g damages to device signal interfaces caused by over voltage or over current of lightning System Grounding Requirements A good grounding system is the basis for the stable and reliable operation of th...

Page 31: ...ir related manuals EMI Considerations Various interference sources from either outside or inside the equipment or application system affect the system in the conductive ways such as capacitive couplin...

Page 32: ...2 000 meters while there may be potential risks above 2 000 meters Precaution for Fiber Connections Before you connect the fibers check that the optical connector type and fiber type match the optical...

Page 33: ...essional devices and should be installed by professionals Confirmations Before Installation Before installation please confirm the following points Whether sufficient airflow is available for the swit...

Page 34: ...launch pad and high frequency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables Interface cables should be laid inside th...

Page 35: ...d any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected Check that all in...

Page 36: ...serial port of the PC Step 2 Connect one end of the console cable RJ 45 to the console port of the switch Setting Terminal Parameters Step 1 Start the PC and run the terminal simulation program on th...

Page 37: ...layed Choose the serial port used currently in the column use when connecting Figure 4 3 After choosing the serial port click OK to display the serial port parameter setting interface set the baud rat...

Page 38: ...irement of the switch The console cable is correctly connected the terminal can be a PC used for configuration is already started the parameters are already configured Checking After Power on Recommen...

Page 39: ...s not on after the switch is started The power supply module does not supply power The power cable is in loose contact Check whether the power socket at the equipment room is normal and whether the po...

Page 40: ...dule is not properly installed or is in loose contact The module is installed after the host is powered on Power off install the module and then power on the host Power off remove and install the modu...

Page 41: ...r of PDs connected to the switch exceeds the rated power range provided by the PoE switch faulty so change the PD Check the total power of PDs If a priority power supply is needed for a specific port...

Page 42: ...four pairs of wires for transmission all of which must be connected 0 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schematic Diagram for the Four Twisted Pairs of...

Page 43: ...T 2 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is...

Page 44: ...mpliance FE SFP LX MM1310 1310 Multi m ode optical fiber 62 5 1 25 2km 14 14 FE SF P LX M M1310 FE SFP LH1 5 SM1310 1310 Single mode optical fiber 9 125 15km 8 8 FE SF P LH15 SM131 0 Mini GBIC S X 850...

Page 45: ...as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet t...