Ruijie  5/8-Port  Plastic  Series  Switches  Hardware  Installation  and  Reference  Guide 

 

current of the system totals 30mA. A leakage protector with 30mA rated action current supports less than ten power 

supplies  (that  is,  Action  current  of  the  leakage  protector/2/Maximum  leakage  current  of  each  power  supply 

=30/2/1.5=10). In other words, the leakage protector with 30mA rated action current supports no more than ten power 

supplies. In this case, the twenty power supplies in the system require at least two leakage protectors with 30mA 

rated action current and each leakage protector supports ten power supplies. If power supplies in a system differ in 

models, the rated leakage action current of each leakage protector divided by two is greater than the sum of maximum 

leakage current of all the power supplies. The rated leakage non-action current of a leakage protector shall be 50% 

of the leakage action current. Take a leakage protector with 30mA rated leakage action current as an example. The 

rated leakage non-action current shall be 15mA. When the leakage current is below 15mA, the protector shall not act. 

Otherwise, misoperation may easily occur due to high sensitivity and thus the leakage protector trips, devices are 

powered off, and services are interrupted. 

 

To guarantee personal safety, the rated leakage action current of each leakage protector in the system must be equal 

to or less than 30mA (human body safety current is 30mA). When twice of the total leakage current of the system is 

greater than 30mA, the system must be equipped with two or more leakage protectors. 

 

For the leakage current value of each power supply model, see the power supply model parameter table in Chapter 

1. 

2.1.4  Static Discharge Damage Prevention 

To prevent damage from static electricity, pay attention to the following: 

 

Indoor dust prevention. 

 

Proper humidity conditions. 

2.2 Installation Site Requirements 

To ensure the normal working and a prolonged durable life of the equipment, the installation site must meet the following 

requirements. 

2.2.1  Ventilation 

Maintain a minimum clearance of 100 mm (3.94 in.) around the device. After various cables have been connected, they 

should be arranged into bundles or placed on the cabling rack to avoid blocking the air inlets. It is recommended to clean 

the switch at regular intervals (like once every 3 months). Especially, avoid dust from blocking the screen mesh on the 

back of the cabinet. 

2.2.2  Temperature and Humidity 

To  ensure  the  normal  operation  and  prolong  the  service  life  of  5/8-port  plastic  series  switch,  you  should  keep  proper 

temperature and humidity in the equipment room. 

If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment may 

be damaged. 

 

In an environment with high relative humidity, the insulating material may have bad insulation or even leak electricity. 

Sometimes the materials may suffer from mechanical performance change and metallic parts may get rusted. 

Summary of Contents for RG-ES05

Page 1: ...Ruijie Reyee 5 8 Port Plastic Series Switches Hardware Installation and Reference Guide...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...om Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Support Email service_rj ruijienetw...

Page 4: ...ase T 1 1RG ES05 Technical Specifications Model RG ES05 Ports Supports 5 10 100 Base TX auto sensing Ethernet ports Power Supply AC input Rated voltage range 100 VAC to 240 VAC Maximum voltage range 9...

Page 5: ...Dimensions W x D x H 108 1 mm x 64 mm x 24 8 mm 4 26 in x 2 52 in x 0 98 in Weight With Package 0 19 kg 0 42 lbs The RG ES05 switch is a class A product In a domestic environment this product may caus...

Page 6: ...blocking vents LEDs LED Panel Identification State Meaning System status LED Off The switch is powered off Solid on The switch is operational RJ45 port status LED 1 5 Off The port is not connected So...

Page 7: ...55032 2015 A11 2020 EN 55035 2017 A11 2020 EN 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 300 386 V2 1 1 2016 07 Security Standards GB4943 2011 EN 62638 1 Earth Leakage Current 1 5mA Dimensions W x D...

Page 8: ...DC power port Heat Dissipation The RG ES08 adopts natural heat dissipation thereby ensuring normal function of the device Maintain a minimum clearance of 100 mm 3 94 in around the device It is recomm...

Page 9: ...o 240 VAC Maximum voltage range 90 VAC to 264 VAC Frequency 50 60 Hz Rated current 0 3 A Adapter output Rated voltage range 5 VDC Rated current range 0 6 A EEE Not supported PoE Not supported Power Co...

Page 10: ...n Weight With Package 0 2 kg 0 44 lbs The RG ES05G switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequa...

Page 11: ...blocking vents LEDs LED Panel Identification State Meaning System status LED Off The switch is powered off Solid on The switch is operational RJ45 port status LED 1 5 Off The port is not connected Sol...

Page 12: ...32 2015 A11 2020 EN 55035 2017 A11 2020 EN 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 300 386 V2 1 1 2016 07 Security Standards GB4943 2011 EN 62638 1 Earth Leakage Current 1 5mA Dimensions W x D x H...

Page 13: ...pation The RG ES08G adopts natural heat dissipation thereby ensuring normal function of the device Maintain a minimum clearance of 100 mm 3 94 in around the device It is recommended to clean the devic...

Page 14: ...uijie 5 8 Port Plastic Series Switches Hardware Installation and Reference Guide Solid on The port is connected at 10 100 1000 Mbps Blinking The port is receiving or sending traffic at 10 100 1000 Mbp...

Page 15: ...be qualified Before installing the device carefully check any potential danger in the surroundings such as damp wet ground or floor Before installing the device find out the location of the emergency...

Page 16: ...r less than 30mA human body safety current is 30mA When twice of the total leakage current of the system is greater than 30mA the system must be equipped with two or more leakage protectors For the le...

Page 17: ...on the equipment may be adhered by the static electricity causing bad contact of the metallic joint Such electrostatic adherence may occur more easily when the relative humidity is low not only affec...

Page 18: ...from the electromagnetic wire or signal cable connection between the source and the sensitive component along which cable the interference conducts from one unit to another Conducted interference ofte...

Page 19: ...les should be laid inside the equipment room and outdoor cabling of such cables is prohibited If outdoor cabling is necessary take relevant measures for lightning protection 3 2 1 Mounting the Switch...

Page 20: ...a table as shown in Figure 3 2 Figure 3 2 Placing the Switch on a Table The device must be installed and operated in the place that can restrict its movement 3 3Checking after Installation Before che...

Page 21: ...add it to the topology If the unmanaged switch is already added to the topology and displayed as a virtual device Select the virtual device and scan its QR code or manually enter its information to t...

Page 22: ...Adding Unmanaged Device Manually 1 Tap Topology to enter the topology page 2 Tap the Topology button and select the existing managed device To add an unmanaged downlink switch manually select Manually...

Page 23: ...Ruijie 5 8 Port Plastic Series Switches Hardware Installation and Reference Guide...

Page 24: ...correctly connected The power supply voltage complies with the requirement of the switch 4 1 2 Checking after Program Startup Recommended After power on you are recommended to perform the following c...

Page 25: ...er cable is in loose contact Check whether the power socket at the equipment room is normal and whether the power cable is plugged in The RJ45 port is not in connectivity or it is erroneous in receivi...

Page 26: ...uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE...

Page 27: ...eference Guide Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic d...

Page 28: ...Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester lightning protect...

Page 29: ...her the grounding line for the arrester is in good contact with the switch grounding terminal and the framework 4 According to the description on the Ethernet Port Arrester Hardware Installation Guide...

Page 30: ...Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to confirm the contac...