Whether related network adaption lines are already laid out
Installing the RG-AM5528
Notes
During installation, note the following points:
Connect the power cables of different colors to the corresponding grounding connectors.
Ensure that the interface of the power supply cable is well connected to the power interface of the device. The power
cables must be protected using power cable retention clips after they are connected to the device.
Do not place any articles on the RG-AM5528 series access point.
Reserve a spacing of at least 10 cm around the chassis for good ventilation. Do not stack the devices.
The access point should be located at places free from the large power radio launch pad, radar launch pad, and
high-frequency large-current devices. If necessary, electromagnetic shielding should be adopted. For example, use
interface cables to shield cables.
100-meter network cables should be laid inside the equipment room and outdoor cabling of such cables is prohibited.
If outdoor cabling is necessary, take relevant measures for lightning protection.
2.1.1 Mounting the Access Point to a Standard 19-inch Rack
The RG-AM5528access point follows the EIA standard dimensions and can be installed in 19-inch rack.
Attach the mounting brackets to the access point with the supplied screws, as shown in Figure 2-1.
Figure 2-1 Attaching the Mounting Bracket to the Access Point