Static Discharge Damage Prevention
To prevent damage from static electricity, pay attention to the following:
Proper grounding of grounding screws on the back panel of the device. Use of a three-wire single-phase socket with
protective earth wire (PE) as the AC power socket.
Indoor dust prevention
Proper humidity conditions
Laser
The RG-AM5528 series access point supports varying models of optical modules sold on the market which are Class I
laser products. Improper use of optical modules may cause damage. Therefore, pay attention to the following when you
use them:
When a fiber transceiver works, ensure that the port has been connected with an optical fiber or is covered with a
dust cap, to keep out dust and avoid burning your eyes.
When the optical module is working, do not pull out the fiber cable and stare into the transceiver interface or you may
hurt your eyes.
Do not stare into any optical port under any circumstances, as this may cause permanent damage to your eyes.
Installation Site Requirements
To ensure the normal working and a prolonged durable life of the equipment, the installation site must meet the following
requirements.
Ventilation
For the RG-AM5528,a sufficient space (at least 10 cm distances from both sides and the back plane of the cabinet)should
be reserved at the ventilation openings to ensure the normal ventilation. After various cables have been connected, they
should be arranged into bundles or placed on the cabling rack to avoid blocking the air inlets. It is recommended to clean
the access point at regular intervals (like once every 3 months). Especially, avoid dust from blocking the screen mesh on
the back of the cabinet.
Temperature and Humidity
To ensure the normal operation and prolong the service life of RG-AM5528 series access point, you should keep proper
temperature and humidity in the equipment room.
If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment
may be damaged.
In an environment with high relative humidity, the insulating material may have bad insulation or even leak electricity.
Sometimes the materials may suffer from mechanical performance change and metallic parts may get rusted.
In an environment with low relative humidity, however, the insulating strip may dry and shrink. Static electricity may
occur easily and endanger the circuit on the equipment.