coordinates. The odd sequence means feeding should be done to one direction and the even
sequence means feeding done to the other direction. The initial direction for the first time can
be changed through setting the directional polarity or modifying the plus and minus values of
the feeding length.
Power-Off-Restart Delay
: it can be set to be 0~3000ms. After the power-off of the
electricity grid, the power supply of the system will not drop to 0 at once. There is a delay
during this time. The delay value set here should basically consistent with the actual off-delay
value. If the deviation of set value is larger, on the de-energizing for continuous engraving,
either the figure processed for the second time is not closed with that before the cutoff, or it is
coincided with that too much.
After the configuration parameters in the manufacturer parameters, such
as directional polarity, control mode, laser type and laser PWM
frequency, are modified, the system should be reset. Such a modification
can function upon the resetting of the system.
Enable parameters
Door Opening Protection
: If this item is enabled, then the door opening protection
must be connected to the controller, or, the machine will not run.
Whether to enable the blower
: If using wind out port to control the blower by the
graph layer parameter, this item must be enabled, or, the wind output is a signal for other using.
9.2 User parameters
(
1
)
Cutting parameters(Only affect cutting arts)
Idle Move Speed
: this parameter decides the highest speed of all non-lighting lines for
the machine in the movement process.
Idle Move Acceleration
: it means the highest acceleration of all non-lighting lines. Idle
stroke speed and idle stroke acceleration can be set higher to reduce the working time of the
whole figure, but if they are set too high, it may cause the jarring of track, so comprehensive
consideration should be given to the setting.
Idle Move Delay
:
If this parameter is zero, then after idle moving there is no delay, or,
there is delay and the speed will decrease to turn off speed.
Turning Speed
: it means the speed of turning at the acute-angle corner, which is also
the highest speed in the whole cutting process.
Prompt