![Ruida Technology RDC6445G Manual Download Page 66](http://html1.mh-extra.com/html/ruida-technology/rdc6445g/rdc6445g_manual_1499556066.webp)
RDC6445G/S Control System manual
SHENZHEN RUIDA TECHNOLOGY
59
Laser Enable
: When double lasers are used, then each laser can be respectively
enabled or disabled.
Minimum Power
Maximum Power
Laser PWM Frequency
Pre-generation Frequency
Pre-generation pulse scale
: When the laser is RF-laser and it
’
s need to pre-generate
PWM, then set the Pre-generation Frequency and the Pre-generation pulse scale.
Water Protector Enabled
: When the water protector is enabled, the mainboard will
detect the input port of water protector. If this port is of low level, it will be deemed normal; if
this port is of high level, the mainboard will forcibly close the laser to suspend the work in
progress and the system will warn. If the water protector is not enabled, the mainboard will not
detect the input port of water protector and so the water protector can be unconnected.
Laser PWM Frequency is used to set the pulse frequency of control signal used by this laser, in
general, glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum power (%) is
used to set the limit power of this laser, that is to say, during the operation, the maximum power set
by the user can
’
t be higher than that set here and the minimum power set by the user can
’
t be less
than that set here, either. When a laser
’
s power is attenuated, then the laser attenuation quotiety
may be set
If it is only provided with the single laser, it can show the one-path
parameter.
(
3
)
Other manufacturer parameters
Machine configuration
Machine Type
: In most cases, the general engraving machine should be selected and
other types used for specific purposes.
Transmission Mode
: generally the
“
Belt Stepping Type
”
should be made choice of. The
control algorithm will be changed a little when other types are selected.
Feeding Mode
: it has single-way mode and two-way mode for option. If it is of
single-way feeding, it is unnecessary to check the coordinates. Feeding can be conducted in the
single-way mode; if it is of two-way feeding, the system will check the maximum and minimum
Prompt