Page 1: ...user is sure to read this manual before using the controller The contents of this manual is the system operating manual Read the manual carefully to ensure proper electrical connection RuiDa Technolog...

Page 2: ...r reduce and modify the products and functions of this product stated herein as well as amend any documents attached to this product without prior notification 3 The users should peruse this manual pr...

Page 3: ...Non metal Distance controller user manual LFS ANM T43 V2 III Shenzhen Ruida Technology Co Ltd Version History Version Date Describe V1 0 2018 03 14 Created...

Page 4: ...CN7 7 2 9 USB interface 8 2 10 Led Indicator 8 2 11 Switch 8 Chapter 3 Function Introduction 9 3 1 Touch Screen Introduction 9 3 2 Function Introduction 10 3 2 1 Main Interface Function 10 3 2 2 Para...

Page 5: ...Non metal Distance controller user manual LFS ANM T43 V2 V Shenzhen Ruida Technology Co Ltd Appendix 1 Usual Fault Disposing Method 22 Appendix 2 Installation method of sensor 24...

Page 6: ...isplacement sensor and laser cutting head Auxiliary gas switch relay Positive and negative limit switches of laser cutting head The motion control system is primarily responsible for the control of th...

Page 7: ...Non metal distance controller includes the following important accessories Non metal distance controller LFS ANM T43 V2 as shown in Figure 1 1 4 3 inch touch screen as shown in Figure 1 2 Touch scree...

Page 8: ...Non metal Distance controller user manual LFS ANM T43 V2 3 Shenzhen Ruida Technology Co Ltd Figure 1 2 touch screen M 3 18mm 37mm M 3 44mm 25mm 20 mm Figure 1 3 Laser displacement sensor...

Page 9: ...he focal plane is 100mm which is changed according to the different sensor models Suppose the distance of the selected sensor is 100mm The center moment of the sensor is 100mm and the detection range...

Page 10: ...D TXD GND AlmOut DnOk UpOk WrkOk Trace 1 2 3 4 CN3 VCC RXD TXD GND 1 2 3 4 Touch screen 1 2 3 4 CN5 5 DrProc FootSw L_IN OUT0 OUT1 2 3 4 4 CN3 CN3 CN5 CN2 RDC633XM 3 CN2 Brown gray blue Shielding laye...

Page 11: ...y 24V connection the channel of touch screen V interface PIN2 TXD Serial read data interface connection the channel of touch screen T interface PIN3 RXD Serial write data interface connection the chan...

Page 12: ...will control the laser head to trace down When high level or open the LFS will rise the laser head 2 7 External power input CN6 PIN SIGNAL DEFINITION DESCRIPTION PIN1 Lmt UP limit Compatible 5V 24V l...

Page 13: ...on metal distance controller GND GND 1 2 4 3 5 CN7 2 If connect servo motor connecting it with relative way according servo driver model and set the servo drive parameters correctly The servo drive is...

Page 14: ...e origin position Rise Height This parameter is the lifting height of the sere cutting status Follow Speed This parameter is the maximum speed of following motion Manual Speed This parameter is the ma...

Page 15: ...he non metal distance control system and go back to origin When you want to reset please make sure you have installed upper limit switch Remarks Do not reset when triggering the lower limit 0 1 You ca...

Page 16: ...ter coefficients cannot prevent the cutting head when breaks down In contrast too small alarm filter coefficient is easy to cause the laser displacement sensor wrong detection to alarm Enable Advanced...

Page 17: ...eed to be set according to the actual situation of the machine Circle Pulse Number It is the number of pulses that the motor rotate one circle If Stepper motor it means motor driven subdivision If ser...

Page 18: ...to facilitate recovery management When restore it will restore the last saved vendor value to user parameter If users are not save this value before restore the default value is restored to the user...

Page 19: ...control is normal or not to avoiding light and no air Test Methods pressure Blow Test It will blow on until the release button stop the air Remarks When testing please make sure the system is idle ot...

Page 20: ...7 System Time In the main interface user can change the time in the touch screen of upper right corner to change Under this interface user can set date and time When entering the interface user will...

Page 21: ...roller connection panel and main board It is need to set correctly vendor paras and user paras of RDC633XM before running In software of MetalCut file vendor setting other Click Enable open cover prot...

Page 22: ...head If the direction of movement is wrong modify the Motor polarity parameter until the movement is normal 5 Press the follow button button to open the following switch display as following open by m...

Page 23: ...anual LFS ANM T43 V2 18 Shenzhen Ruida Technology Co Ltd 1 Set the layer parameters correctly After set a correctly vendor parameters user parameters and processing parameters which can be cutting 2 T...

Page 24: ...Press pulse to test whether the laser is normal or not 5 positioning To move the head to a cutting position On the panel press the Position button as a reference point 6 Frame After positioning press...

Page 25: ...point need to re power the non metal distance controller if the power is still repeated to show the system error the non metal distance controller is not normal 5 2 Upper and lower limit trigger When...

Page 26: ...r coefficient reasonably 5 5 Emergency stop When the emergency stop input is low an emergency stop is triggered If the actual emergency stop input is not low It will emergency stop Terminal wiring is...

Page 27: ...acceleration or speed is set improperly Reduce the acceleration or speed Touch screen display Can not connect Wrong connection of touch screen and non metal distance controller To check the touch scr...

Page 28: ...da Technology Co Ltd The filter factor is set too large Reduce the filter coefficient Servo drive rigid setting is too large Reduces servo rigidity Misoperation trigger beyond the detection range duri...

Page 29: ...on height can t be adjusted by 0 It can be installed in an appropriate position and record the display number of the sensor and then set the focus shift through the touch screen and it can also be use...

Page 30: ...a Technology Co Ltd Without our permission any company or individual shall not reprint copy or distribute the content related to this product manual We keep the rights to revise or update the contents...