![Ruida Technology LFS-ANM-T43-V2 User Manual Download Page 16](http://html1.mh-extra.com/html/ruida-technology/lfs-anm-t43-v2/lfs-anm-t43-v2_user-manual_1499563016.webp)
Non-metal Distance controller user manual LFS-ANM-T43-V2
11
Shenzhen Ruida Technology Co., Ltd.
3.2.2 Parameters Setting
It can set the parameters from “Menu” main interface. Including process parameters, height
parameters, speed parameters, machine parameters etc.
Remarks
: Please setting parameters correctly when using the non-metal distance
controller, otherwise, the non-metal distance controller cannot work.
The meanings of the parameters are shown in the following
:
Technical
Para
Filter Factor
Increase these parameters to improve the response
speed of the following. But it is easy to shock when
moving. Please set suitable parameters.
Alarm filter
This parameter should not be set too large. Excessive
alarm filter coefficients cannot prevent the cutting
head when breaks down. In contrast, too small alarm
filter coefficient is easy to cause the laser
displacement sensor wrong detection to alarm.
Enable
Advanced
Blowing
In the enable status
,
Once start processing will blow
air until the work finished
Following
Acceleration
Acceleration Limits during following moving
Height Para
Rise Height
It is the height of the lifting during the cutting
process
。
Alarm Height
It is the height of the non-metal controller lifting
automatically that trigger lower limit or beyond
detection range during following moving.
Standby
height
It is the height of the cutting head when finished
cutting.
Focus Offset
It is the offset of actual position of the focus to the
zero position and the position of movement of the
cutting head to maintain stable.
Reset Height
The distance of moving downward touching upper