Non-metal Distance controller user manual LFS-ANM-T43-V2
10
Shenzhen Ruida Technology Co., Ltd.
3.2 Function Introduction
3.2.1 Main Interface Function
“
FOLLOW ON/OFF
”
:
It is use to turn on /off follow status. When turn on, Non-metal
distance controller adjust the cutting head automatically by current parameters and move in
the focus position. When turn off, it cannot control the cutting head.
“SPEED FAST/SLOW”
:
It is used to change speed fast/slow. When fast speed, the manual
movement maximum speed is manual high speed. When slow speed, the manual movement
maximum speed is manual slow speed. In the touch screen data display area "Manual speed”,
it can view the current manual speed
“Menu”
:
it can setting the parameters and parameters manager from manual
“Reset”
:
it can reset the non-metal distance control system and go back to origin. When you
want to reset, please make sure you have installed upper limit switch.(Remarks: Do not reset
when triggering the lower limit)
“±0.1”
:
You can modify the focus offset online
,
Fine-tuning the cutting head
,
increase or
decrease 0.1mm each time. Reads the current focus offset from the data display area of
“Focus Offset”.
“Up and down”
:
It can control the cutting head moving up and down,press the bottom to
start. It will stop when trigger limit switch or release the bottom.
“Alarm Info”
:
It can enter into the interface of alarm information, to check the details record
of alarm. It can record 9 times of alarm information.
“Function”
:
It can enter the interface of blowing test function. Press “blow testing”, blowing
on, when you release the bottom will stop.
“System Info”
:
You can change the touch screen language and check the non-metal distance
controller software version number
“System time”
:
it can change the system time
。