Injector IR 29
14
5.1
Regular care
Regular care of the machine must be carried out at least once per
week. This prevents malfunctions and signs of wear.
Any abnormalities detected during regular care must be reported to
the supervisor! He must immediately initiate correction or mainte-
nance or notify Rühle Service!
Care schedule:
a)
Disassemble the machine according to the cleaning instruc-
tions. Check for any parts moving with difficulty, material
abrasion or other signs of wear and tear!
b)
Check softer blades for wear and tear, damage or broken
blades!
c)
Check curing needles for wear, damages and clear passage!
d)
Check the needle system for leakage integrity!
e)
Inspection of all safety switches as outlined in Chapter 1.1
Safety Instructions!
f)
Check the steering rollers and locking devices for damages
and proper function!
g)
Visually check for changes or damages on all machine sides
and accessible machine parts, e.g. needle bar. The machine
must be shut down in the event of any damages or changes!
5.2
Regular maintenance
Regular maintenance of the machine must be carried out every 2000
hours of operation but at least once per year.
Maintenance schedule:
a)
Inspect the safety devices as outlined in Chapter 1.1 Safety
Instructions!
b)
Read the error memory (frequency converter)!
c)
Replacement of the needle seals in the needle register!
d)
Check curing needles for wear, damages and clear passage!