![ruegg Flex-Line series Installation Manual Download Page 25](http://html1.mh-extra.com/html/ruegg/flex-line-series/flex-line-series_installation-manual_1499072025.webp)
Flex-Line
Installation manual
__________________________________________________________________________________
25
25
In the case of non-combustible mounting surfaces (country-specific definition), primary walling can be
dispensed with.
Thermal insulation with reference insulation at a 10cm primary walling
Device
Air gap
excluding
mantle
[cm]
Thermal insulation excluding
mantle
With Primary walling 10 cm
[cm]
Air gap
including
mantle
[cm]
Thermal insulation including mantle
With Primary walling 10 cm
[cm]
Violino 45x60
6
14
0
14
Violino 45x80
6
14
2
14
Violino 55x73
6
14
2
14
Violino 55x98
6
14
2
14
Violino 65x87
8
14
2
14
RIII 45x56x46
4
12
-
-
RIII 45x56x60
4
12
-
-
RIII 45x56x80
4
12
-
-
RIII 45x80x46
4
12
-
-
RIII 45x100x46
4
12
2
12
RIII 55x100x46
4
12
2
12
Thermal insulation with Silca 250KM as a replacement for primary walling and reference insulation
Device
Air gap
excluding
mantle
[cm]
Thermal insulation excluding
mantle
Incl. primary walling
[cm]
Air gap
including
mantle
[cm]
Thermal insulation including mantle
Incl. primary walling
[cm]
Violino 45x60
6
12
0
12
Violino 45x80
6
12
2
12
Violino 55x73
6
12
2
12
Violino 55x98
6
12
2
12
Violino 65x87
8
12
2
12
RIII 45x56x46
4
10
-
-
RIII 45x56x60
4
10
-
-
RIII 45x56x80
4
10
-
-
RIII 45x56x46
4
10
-
-
RIII 45x100x46
4
10
0
10
RIII 55x100x46
4
10
0
10