![Ruby 025 FDA Installation, Operation And Maintenance Manual Download Page 14](http://html1.mh-extra.com/html/ruby/025-fda/025-fda_installation-operation-and-maintenance-manual_1498638014.webp)
14
4.0 Pump Disassembly
Step 1
Remove the discharge manifold by untying
the screws in X formulation
Step 2
Remove the balls and the seats. Reverse
the pump and remove the suction manifold
with the same way
Step 3
Untie one of the two housings, by untying the
screws gradually and cyclically.
Step 4
Detach the diaphragm from the central
block by hand and untie it with a left rotation.
Step 5
Untie the opposite housing and pull the
diaphragm along with the shaft outwards.
Remove the diaphragm from the shaft
Step 1 - Step 2
We remove the safeties (step 1) and push
from the one side the air control unit to-
wards the outer part (step 2)
4.1 Air control valve disassembling