Peakmeter series 115..G/115..G-xxx
Specifications Page B-1
Appendix B:
Specifications
General
Supply voltage:
24 V DC ±10 %
Current drain:
max. 190 mA
Operating temperature range:
+5° to +45° Celsius
Scale length:
127mm (5 inch)
Number of display segments:
201 segments/channel
Type of display:
Neon-plasma-bargraph display
Colour of display:
orange
In- and output:
xformer-balanced, floating,
according AES standard
Input impedance:
110
Ω
or High-Z
Sample rate:
27 kHz to 96 kHz
Overload detector:
adjustable word width, number of
samples and threshold
DC-filter:
OFF or 5 Hz
Memory accuracy (Memo):
±1 segment
Weight:
approx. 700 g (1.6 lbs) net
Dimensions:
190 x 40 x 107 mm
Connector:
64 pin connector DIN 41612A/C
115..G Digital scale
Scale range:
-60 dB to 0 dB
Brighter scale marks:
-50, -40, -30, -20, -10 dB
Brighter scale range:
starting with begin of headroom
Scale graduation:
according IRT-recommendation 3/6
Integration time:
sample
Gain:
+40 dB
Peakhold:
sample spot
Peakhold reset time:
auto (approx. 2.5 s) or manual
115..G-DIN Analog scale
Scale range:
-50 dB to +5 dB
Input sensitivity for reference 0:
Selected headroom value
(EBU rec. -9 dB FS)
Brighter scale marks:
-40, -30, -20, -10, -5 dB
Brighter scale range:
0 dB to +5 dB
Additional scale marks:
-25 dB, -15 dB and from
-10 dB to +5 dB in 1 dB-steps
Scale graduation; integration time:
10 msec, switchable according
IRT-recommendation 3/6
Gain:
+20 dB
Peakhold:
sample spot
Peakhold reset time:
auto (approx. 2.5 s) or manual
Summary of Contents for 115 G Series
Page 16: ...Peakmeter Serie 115 G 115 G xxx Seite 2 8 Erste Schritte ...
Page 22: ...Peakmeter Serie 115 G 115 G xxx Seite 3 6 Kalibrierung und Fehlersuche ...
Page 32: ...Peakmeter series 115 G 115 G xxx Page 5 8 Getting started ...
Page 38: ...Peakmeter series 115 G 115 G xxx Page 6 6 Calibration and Troubleshooting ...