Summary of Contents for VHD-8

Page 1: ...1 It s Under Control VHD 8 Installation and Operation Guide 70 210132 16 V1 2 8x8 HDBT Video Matrix Switch It s Under Control...

Page 2: ...8x8 HDBT Video Matrix Switch VHD 8 2 2 Copyright 2017 Remote Technologies Incorporated All rights reserved...

Page 3: ...onnect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part...

Page 4: ...it Power Cord Grounding Plug Do not remove the grounding prong of the grounding type plug A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety I...

Page 5: ...nt is subject to change without notice Remote Technologies Incorporated shall not be liable for errors or omissions contained herein or for consequential damages in connection with the furnishing perf...

Page 6: ...an application or environment other than that for which it was intended improper installation procedures or adverse environmental factors such as incorrect line voltages improper wiring or insufficie...

Page 7: ...duct Contents 10 Chapter 2 Features and Description 11 Front Panel 11 Rear Panel 12 Chapter 3 Installation and Operation 14 Precautions 14 Mounting 14 Connections 15 Front Panel Control 16 EDID Manage...

Page 8: ...8x8 HDBT Video Matrix Switch VHD 8 8...

Page 9: ...to 230 feet 70m over a Cat5E 6 cable 115ft 35m at 4Kx2K HDBaseT outputs supports PoC Power over Cable to power VHR receivers Supports multiple control methods including front panel RS232 IR and TCP IP...

Page 10: ...mm mono to mono IR cables One 1 Installation Guide UNPACKING AND INSPECTION After unpacking the VHD 8 HDBT Matrix Switch save all of the packing materials in case you ever have to ship the unit Thorou...

Page 11: ...in this order 1 ALL ENTER EDID management button manually capture and copy the EDID data from output device to input port Example To capture and copy the EDID data from output channel No 4 to input c...

Page 12: ...BT HDBT N27917 HDBT AUDIO L R AUDIO L R AUDIO L R AUDIO L R AUDIO L R AUDIO L R AUDIO L R RS232 VHD 8 REAR PANEL CHAPTER 2 DESCRIPTION 1 IR IN 1 8 3 5mm Mono Mini Connect to the IR output of a control...

Page 13: ...used 5 IR CTRL 3 5mm Mono Mini Connect to control processor IR output for control of the VHD 8 6 IR ALL IN 3 5mm Mono Mini IR control signal input port connect to the IR output of a control system IR...

Page 14: ...s with Cat5e 6 cable NOTE The VHR 1 is PoC Power over Cable compatible It can be powered over the same Cat5e 6 cable or a local power supply may be used CONTROL OPTIONS 5 Connect the RS232 port 9 pin...

Page 15: ...15 It s Under Control CHAPTER 3 INSTALLATION AND OPERATION CONNECTION DIAGRAM MEDIA SERVER SAT DVD VHR 1 Receiver Audio Distribution Projector HDTV LAN Processor STREAMER DVD Power...

Page 16: ...Operation Select INPUT ALL ENTER Example Switch input 1 to all outputs Note Indicators of the pressed buttons will blink green for three times if the switch is done then turn off If the switch operati...

Page 17: ...h among the 6 embedded EDID data Then press ENTER to confirm invoking Format Press and hold EDID for 3 seconds INPUTS OUTPUTS 1 6 ENTER Operations 1 Invoke embedded EDID data for one input Operation P...

Page 18: ...an operation When you press CLEAR the matrix will return to the previous status CHAPTER 3 INSTALLATION AND OPERATION FUNCTION ITEMS EXAMPLE DESCRIPTION Check the connection status of inputs IN 1 2 3...

Page 19: ...e IR signal connected to IR ALL IN must be with IR carrier RS 232 CONTROL RS 232 Control of VHD 8 RS232 port A DB 9 jack offers RS 232 control of the VHD 8 from an RTI or third party control system A...

Page 20: ...WEB INTERFACE The VHD 8 web interface is accessible via a standard web browser Chrome Internet Explorer Firefox Safari etc on a PC tablet or smartphone The web interface is used for configuring netwo...

Page 21: ...21 It s Under Control CHAPTER 3 INSTALLATION AND OPERATION WEB INTERFACE LOGIN To access the web interface enter the password and press LOGIN NOTE The default password is rti...

Page 22: ...tic IP address into your web browser address bar to access the web interface again To set the static IP address 1 Select Address Type set to DHCP by default click this button and select Static IP from...

Page 23: ...23 It s Under Control CHAPTER 3 INSTALLATION AND OPERATION WEB INTERFACE...

Page 24: ...ject to change without notice GENERAL Video Input Eight HDMI Input Level T M D S 2 9V 3 3V Input Impedance 100 Differential Video Output Four HDMI Eight HDBaseT RJ45 Output Level T M D S 2 9V 3 3V Out...

Page 25: ...k IR CTRL compatible with industry standard IR repeaters and receivers Remote Source IR Inputs Eight discrete IR IN One universal IR ALL IN 3 5mm jacks Panel Control Twenty Front Panel buttons Serial...

Page 26: ...nput output end 2 Make sure the connection is good 3 Send command Y X 1 4 Switch for another input source or enable the display to learn the EDID data of the input SYMPTOM Cannot control the device vi...

Page 27: ...ip IR ring Gnd 2 Adjust IR signal going into VHD 8 3 Verify connection is to IR CTRL input jack SYMPTOM No IR control via VHR 1 CAUSES 1 Faulty wiring 2 IR signal level 3 IR emitter or IR emitter plac...

Page 28: ...model and serial number if applicable If you are having a problem with hardware please note the equipment in your system a description of the problem and any troubleshooting you have already tried If...

Page 29: ...ip the VHD 8 for service Please pack it securely we suggest that it be insured Do not include accessories such as power cords or manuals unless instructed to do so You must pay any shipping charges in...

Page 30: ...8x8 HDBT Video Matrix Switch VHD 8 30 NOTES...

Page 31: ...31 It s Under Control...

Page 32: ...VHD 8 32 Remote Technologies Incorporated 5775 12th Avenue East Suite 180 Shakopee MN 55379 Tel 952 253 3100 Fax 952 253 3131 www rticorp com 2018 Remote Technologies Inc All rights reserved Printed...