background image

Page 5 of  5

Function Tests

RECOVER REFRIGERANT FROM HOSES TO TEST RECYCLE PROCESS:

1. Press 

[

_

_

_

_

key ONE time. The display will show 

WEIGHT = XX.X LB - RECYCLE?

.

2. Press [

ENTER] 

key. The display will show 

RECYCLE HOLD - TIME 02 MIN

. The default minimum time is two

minutes. Do not make any change.

3. Press [

ENTER]

 key. Display will show 

CHECK HOSES - START?

.

4. Press 

[ENTER]

 key. Display will show 

WEIGHT = XX.X LB - COMPRESSOR ON

. The refrigerant in the high and

low side hoses will be recovered. The high and low pressure gauges will show the pressure decrease until a
vacuum is reached. The compressor will shut off and the display will show 

WEIGHT = XX.X LB - COMPRESSOR

OFF

. The two minute recycle hold timer will start. The display will show 

AMOUNT RECYCLED = XX.X LB

 after

the two minutes has elapsed.

5. Press 

[ENTER] 

key to end the process.

CONGRATULATIONS

THANKS 

Performing these tests demonstrated that the RHS780 is operating correctly.

NOW IT’S TIME TO MAKE SOME MONEY

The best suggestion we can offer is that you quickly browse the Operation Manual before using
the RHS780 to perform an actual A/C service. Then, during the first few uses, refer to the
Operation Manual and follow the instructions as each process is performed.

The RHS780 was carefully designed to be intuitive to use. The display screens prompt for input
as required and always ask for confirmation before starting a process.

It’s very important that you follow the Operation Manual the first few times to become familiar with
the techniques of using the RHS780 for A/C service. Then you will find that the display screens
will give you adequate prompts for future use.

4075 East Market Street

York, Pennsylvania 17402

Phone: 800-468-2321

Fax: 717-755-8304

E-mail: [email protected]

Web-site: www.rtitech.com

Summary of Contents for RHS780

Page 1: ...our new machine survived any rough handling it may have experienced during transport 2 Immediately report any visible damage to the unit Save the shipping carton for inspection by a claims adjuster Call RTI Technologies at 800 468 2321 ext 259 for instructions 3 Cut and remove all hold down straps including the one underneath the front of the unit 4 Remove protective plastic cover 5 Carefully tip ...

Page 2: ...Hose 3 Connect other end of Red Hose to left port when facing back of unit on rear of RHS780 The port has a red band 4 Install Blue Field Service Coupler on end of Blue Hose 5 Connect other end of Blue Hose to right port when facing back of unit on rear of RHS780 The port has a blue band 6 The Field Service Couplers should be connected to the parking fittings on the front of the RHS780 when not in...

Page 3: ...frigerant up side down 2 Connect the anti blowback valve end B of the 30 inch yellow hose to the fill port on the side of the RHS780 3 Plug in power cord and press top of power selector switch The display will show WEIGHT XX X LB AUTOMATIC 4 Press _ key four times The display will show WEIGHT 00 0 LB FILL CYLINDER 5 Press ENTER key The display will show CHECK HOSES START 6 Open valve on tank of ne...

Page 4: ...pump will start running Watch the High and Low pressure gauges to verify that the pressure drops into a vacuum as the red and blue hoses are evacuated The display will show PUMP OFF XX MIN CONTINUE at the end of two minutes 10 Press ENTER key The display will show WEIGHT XX X LB AUTOMATIC Continue to next test FILL HOSES AND TEST CHARGE PROCESS 1 Press _ _ _ _ key three times The display will show...

Page 5: ...sed 5 Press ENTER key to end the process CONGRATULATIONS THANKS Performing these tests demonstrated that the RHS780 is operating correctly NOW IT S TIME TO MAKE SOME MONEY The best suggestion we can offer is that you quickly browse the Operation Manual before using the RHS780 to perform an actual A C service Then during the first few uses refer to the Operation Manual and follow the instructions a...