- page 10 of 13
–
Inst ruct ion and operat ing manual GHH
CS750 direct driven
(for-030/031013)
5.2
WEEKLY INSPECTION
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
ONLY CARRY OUT WHEN INSTALLATION IS COOL AND AT A STANDSTILL
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
A:
Check the level of lubricating oil w eekly.
To achieve longevity of the compressor it is important the oil level remains betw een
the indicated marks on the dip-stick (do not overfill).
B:
Check the air intake filter at regular intervals. Clean or replace the air filter if
necessary.
* Please note that the air filter is reinserted in the same position (paying attention
to the front and back of the element).
Image 5.2.1
Also check the functioning of the air indicator.
C:
It is important to check the airflow and cleanliness of the fan louvres to prevent
overheating of the compressor.
(compressed air cooler and w hen installed the oil cooler)
D:
Check the functioning of the fan.
This check may only be carried out by skilled mechanics. Observe the safety very
carefully, the enclosure must be removed and rotating parts will be accessible.
E:
If the installation is equipped w ith an external oil-cooler check if the control light is
on (image 3.1.2). You w ill find the safety fuse in the sw itch box.