Real Time Automation, Inc.
37
1-800-249-1612
150-199
Nodes 150-199 give the email addresses used for messages sent to nodes 50-99. There is
1 address per message, so each node is in a 1-1 relationship with the other.
200
Defines URL links. These are shown in the 515RTAENI web configuration in the
tab on the Utility tab. The 515RTAENI does not validate the URL.
The serial controller sends a write message to node 200 and the URL offset to define a
new link on the Reference Links web page. Only one link is sent per write message. The
controller uses a 485CIF write, where the URL string data is the write data, and the Offset
value defines which URL link to define. Each URL string can be up to 45 characters.
Offset
Link
4
1
6
2
8
3
10
4
12
5
14
6
16
7
18
8
20
9
22
10
201
A write to node 201 is used to change the Data Description column displayed on the Data
View web page. Up to 40 elements can be written, since there are 40 labels, but each
element is written as one data transmission. In other words, the string and the element
offset is written 40 different times to write 40 labels. Each write has the form of
label/offset.
202
Integer data for display on the Data View page is written to node 202, offset elements 0 to
27. The Integer data written is displayed in the “Write from Controller” column.
203
Floating-point data for display on the Data View page is written to node 203, offsets
elements 0 through 11. The data written is displayed in the “Write from Controller”
column.