Real Time Automation, Inc. 

1-800-249-1612 

 

7. Enabled force of at least 1 Admin when security is enabled. 
8. Minor webpage layout fixes. 

 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for 515ENI-N34

Page 1: ...515RTAENI N34 Protocol Gateway Product User Guide Firmware Version 4 02 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...consequential damages therefore the limitations set forth in this agreement may not apply to you No patent liability is assumed by Real Time Automation with respect to use of information circuits equipment or software described in this manual Government End Users If this software is acquired by or on behalf of a unit or agency of the United States Government this provision applies The software a w...

Page 3: ...14 Committing Changes to the Gateway 15 Network Tab 16 Ethernet Settings 16 Changing from DHCP to Static IP 17 Additional Fields under Ethernet Settings 17 Serial Settings 18 Email Settings 19 Email Alarms and Messages 20 Email Message Example 21 Data View Tab 22 Mapping Tab 23 Utility Tab 25 Export Import Configuration 25 Import Configuration 25 Export Configuration 25 Restart Gateway 26 Upgrade ...

Page 4: ...c Tab 32 Ethernet Status 33 Ethernet Status Counters 33 Ethernet Diagnostics Tab 34 LED Behavior 35 DF1 Node Descriptions Reference Table 36 Easily replace an existing NETENI device 39 Using RSLinx and RSLogix 40 EtherNet IP Driver 40 Ethernet Driver 43 Troubleshooting RSLinx and RSLogix Comms 44 Application Specific Tips 45 PanelView Plus Comms 45 Kepware Communications 48 All manuals and user gu...

Page 5: ...iew Duplicate Packet Detect communications fix 3 BootP fixes 4 Data View webpage floating point writes fixed 5 Minor webpage layout fixes 6 Change to force at least 1 admin to Full Access when security enabled 3 32 3 14 2017 Bug Fixes 1 Disabled force of at least 1 Admin when security is enabled see change 6 in version 3 31 4 02 7 26 2017 Bug Fixes 1 Updated web UI diagnostics and counters 2 Added...

Page 6: ...Real Time Automation Inc 6 1 800 249 1612 7 Enabled force of at least 1 Admin when security is enabled 8 Minor webpage layout fixes All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...ail Transport Protocol SMTP Allows ability to easily upload and download programs using standard Rockwell Automation tools Writes to Ethernet controllers like ControlLogix However the interface is improved by providing web browser configuration allowing up to 12 Ethernet connections adding support for string data types and improving diagnostic functionality If at any time you need further assistan...

Page 8: ...wer can be received over serial cable TEMPERATURE Industrial Temperature Range 40C to 85C CERTIFICATIONS UL C UL CE FCC CLASS 1 DIV 2 MOUNTING Din Rail Panel SIZE 4 2 x 3 25 x 1 WEIGHT 5 oz COMMUNICATION PORTS SERIAL 1 RS232 ETHERNET 1 10 100 Mbps BaseT Ethernet Port All manuals and user guides at all guides com ...

Page 9: ...ing the 515RTAENI against the rail press down to engage the spring loaded upper clip and rotate the unit parallel to the DIN Rail 4 Release downward pressure Removing Follow these steps to remove your interface converter 1 Press down on unit to engage the spring loaded upper clip 2 Swing bottom of unit away from DIN Rail DIN Rail Spring Loaded Upper Clip All manuals and user guides at all guides c...

Page 10: ...ARD Substitution of components may impair suitability for Class I Division 2 THIS EQUIPMENT IS AN OPEN TYPE DEVICE AND IS MEANT TO BE INSTALLED IN AN ENCLOSURE SUITABLE FOR THE ENVIRONMENT SUCH THAT THE EQUIPMENT IS ONLY ACCESSIBLE WITH THE USE OF A TOOL WARNING POWER JACK Barrel Connector J1 IS FOR MAINTENANCE USE ONLY AND MAY ONLY BE USED WHILE THE AREA IS KNOWN TO BE FREE OF IGNITIBLE CONCENTRA...

Page 11: ...in 2 RX Pin 3 TX Pin 5 GND CABLE INFORMATION Wiring It is recommended to use Allen Bradley serial cables Allen Bradley 1761 CBL PM02 Ser C Allen Bradley 1756 CP3 IMPORTANT It is highly recommended to follow wiring recommendations regarding the Allen Bradley serial cables Failure to do so may result in poor or inoperable intermittent communications NOTE Only one physical port can be used at a time ...

Page 12: ...2 Run the IPSetup exe program from the CD ROM 3 Find unit under Select a Unit a If you do not see the gateway in this tool then your PC is most likely set up as a static IP i Change your PC s network settings to be DHCP If DHCP fails then it will change to be on the 169 254 x y network ii Relaunch the IP Setup tool to see if gateway can be discovered now 4 Click Launch Webpage The Main page should...

Page 13: ... 2 The gateway must be on the same Network Subnet as the PC whether it s setup for DHCP or Static Once you have both devices on the same network you should be able to ping the gateway using a MS DOS Command Prompt The image above shows a gateway that is currently set to a static IP Address of 192 168 0 100 If you successfully ping your gateway open a browser and try to view the main page of the ga...

Page 14: ...rmation can be found on each one 1 Home used for diagnostics and status messages for both the DF1 and Ethernet sides 2 Data View used to read write and display data from the Controller 3 Network used to configure all Ethernet E mail and Serial Port Settings 4 Mapping used to configure all the IP Address DF1 Node mappings 5 Utility used for revision information downloading the EDS file updating fir...

Page 15: ...will change into text boxes or dropdown lists See below screenshot as an example The only field in this section that isn t configurable is the Serial Mode Changes will not take effect until the Save button is clicked While the save is in progress the Save button will change into the icon to indicate that the gateway is currently saving those settings If the Ethernet settings are changed the gatewa...

Page 16: ...me that the gateway is powered up If DHCP fails then an AutoIP Address is used to make the webpages accessible and DHCP will continue to attempt to get an address 2 Static IP An IP Address is statically set and will never change until the option is modified When configuring a static IP be sure to update the appropriate values in IP Address Subnet Mask and Gateway fields All manuals and user guides...

Page 17: ...he network where the gateway looks up IP Addresses This is mandatory for E mail PLC Security Mask 1 This field limits what controllers can connect to and communicate with the gateway based on their IP Address This can be used to only allow a specific IP Address or a specific IP Address range The value 255 is the wildcard value A value of 0 0 0 0 or 255 255 255 255 allows any Ethernet device to con...

Page 18: ...rial Mode Cannot be changed DF1 RS232 8N1 8N1 meaning 8 data bits no parity bit 1 stop bit Timeout ms Elapsed time in milliseconds for sending or receiving data before an error is reported DLE NAK Retries Response that signals that a message frame was not received successfully DLE ENQ Retries Requests retransmission of a response DLE Embedded Response Per the DF1 protocol this allows a response to...

Page 19: ... Email Server requires SMTP Authentication If the Email Server does not require SMTP Authentication then the values here will be ignored and can be left blank The maximum length for these fields is 64 characters From Email Address This is an ASCII string that cannot be left blank so by default it is filled in with a default value that can be modified This is the message that is sent with any email...

Page 20: ...arded to the associated To address The controller will send a 485CIF Write message to the DF1 destination Node that is mapped to the destination email address For the 515RTAENI to successfully send an email message the Email Settings configuration needs to be setup correctly The 515RTAENI stores the destination email address but does not store the actual data that is sent Field Description Destn M...

Page 21: ...tination email address In this case since we are writing to Node Address 50 the e mail address that would be used would be what is configured in Node Address 150 in the gateway s webpage The format of the email subject line is 515RTAENI MSG This is how the MSG instruction would look NOTE The two screenshots above display File Name ST10 0 as a specific example For the user the email message data wo...

Page 22: ...ws 40 user configurable descriptions for the reads and writes associated with the Data Table Address ranges of N50 0 27 and F51 0 11 Depending on the Refresh Rate configured at the top of the screen values written from that location in the controller will display in the Write from Controller column Values can be entered in the Write to Controller column and when the Write button is pressed those v...

Page 23: ...troller Configurable Mapping Node The 515RTAENI can route a DF1 message received from the attached controller to a compatible destination TCP IP device using DF1 Node addresses 0 through 49 Config 515RTAENI Node addresses 100 through 149 store destination IP addresses IP Address When the 515RTAENI receives a write message to Nodes 100 to 149 it stores the destination IP address in the correspondin...

Page 24: ...ation Inc 24 1 800 249 1612 IP Routing Table example Configure Node 100 Function Configure route 0 address Execute Node 0 Function Send message to IP address DF1 Node 100 All manuals and user guides at all guides com ...

Page 25: ...ly saved configuration file Import Configuration 1 Click the Choose File button and search for the configuration to load into the gateway 2 Click the Upload button to begin installing the selected configuration file If the load failed an error message will display If successful the message Import Successful Using New Config will appear on the webpage Export Configuration 1 Click the Save Configura...

Page 26: ...will automatically install and the gateway will automatically reboot after the new firmware has been upgraded The upgrade process will take approximately 30 seconds EtherNet IP EDS File This link allows the EtherNet IP EDS file to be downloaded directly from the gateway s web server Right click on the filename link below and select Save Link Target As to store the EDS file to the client PC Other R...

Page 27: ...ata strings can be displayed here by writing to Node 204 at element 0 with the newest event log displayed at the top Either a string write to Node 205 or a click on the Clear Event Log button will clear the buffer If event log is full and a new event is received the new event will overwrite the oldest event in the list All manuals and user guides at all guides com ...

Page 28: ... have Full Access or View Only access to all the gateway s configuration pages Username Enter a name for the security user up to 32 characters Password Enter a password for the security user up to 32 characters case sensitive Hint Enter an optional hint that can be displayed for the security user up to 32 characters Admin Contact Information Enter up to 63 different character s worth of informatio...

Page 29: ...Real Time Automation Inc 29 1 800 249 1612 All manuals and user guides at all guides com ...

Page 30: ...ommunication problems There is also a logging table that can be used to further troubleshoot the Ethernet Serial and general gateway problems Msg Log Tab This tab displays the gateway s internal system status log messages and is only used for advanced troubleshooting The log can be filtered by Start Up Error Event Assertion Serial or TCP messages All manuals and user guides at all guides com ...

Page 31: ...l controller Total Num Messages Enqueued Displays the total number of DF1 messages that are placed into the Waiting to be processed queue Total Num Messages Dequeued Displays the total number of DF1 messages that are removed from the Waiting to be processed queue Total Num Bad BCC CRC Frames Displays the total number of corrupted DF1 messages that have been received Total Num Message Timeouts Disp...

Page 32: ... Bad BCC CRC or Display Queue Full The columns are briefly described as follows Field Description DF1 Node DF1 message destination or source Node Req TX Number of requests transmitted Rsp RX Number of responses received Req RX Number of requests received Rsp TX Number of responses transmitted Timeouts Number of message timeouts for that DF1 Node Queue Full Number of times the processing queue was ...

Page 33: ...od is set to 2 minutes Total Num Messages Discarded Displays the total number of Ethernet messages that have been discarded Total Num Bad Packets Displays the total number of corrupted Ethernet messages that have been received This should be 0 Current Num Sockets Used Displays the current number of open TCP sockets used by the gateway The gateway can support up to 12 sockets at a single time Max N...

Page 34: ...ic IP Address if desired The columns are briefly described as follows Field Description IP Address IP Address associated with the connection Port Remote Port associated with the connection TX Number of packets transmitted RX Number of packets received IN OUT Identifies a connection as either a client OUT or server IN Errors Number of connection errors IP Blocked Number of blocked connection attemp...

Page 35: ...tive communications Idle Blink Red No active communications Timeout Solid Red Fatal Error LED 2 Ethernet Status Solid Green Ethernet Communication is active and messages are successful Blink Green No active communications Idle Blink Red Ethernet cable is connected but there are no active valid communications Idle Timeout Solid Red Fatal Error Off Ethernet cable is unplugged All manuals and user gu...

Page 36: ... 100 Therefore a message sent to Node 0 is sent to the IP address stored in Node 100 Mapping Tab p23 50 99 Writes to Nodes 50 99 are used by the serial controller to send email messages The controller generates a 485CIF write message with the email text as the data to a Node number that maps to the email destination address Email Alarms and Messages p20 100 149 IP addresses mapped with Nodes 0 49 ...

Page 37: ...e 201 is used to change the Data Description column displayed on the Data View webpage Up to 40 elements can be written since there are 40 labels But each element is written as one data transmission In other words the string and the element offset is written 40 different times to write 40 labels Each write has the form of label offset Data View Tab p22 202 Integer data for display on the Data View...

Page 38: ...45 not used 248 A controller write to Node 248 will cause the 515RTAENI gateway to save configuration settings and re initialize 249 Email address The 2nd element is the length of the email address and the 3rd is the email address The ST15 0 is a file and offset in the target Ethernet device That will of course vary by device Email Settings p19 ST15 0 17 12345679 abc com 250 A controller write to ...

Page 39: ...ration tool If you are doing a device replacement just use the ENI ENIW Utility tool to get the configuration file from the old ENI and then do a Save To the 515RTAENI gateway Note If you were previously using a BOOTP IP acquisition mode with your 1761 NET ENI the 515RTAENI will revert to DHCP The BOOTP modes are not supported by the 515RTAENI All manuals and user guides at all guides com ...

Page 40: ... 3 First verify that the 515RTAENI serial port is configured to the correct baud rate for the PLC and then configure the RSLinx EtherNet IP driver IMPORTANT In RSLinx the EDS file for the 515RTAENI must be installed for RSLinx to recognize the device type The EDS file can be downloaded from the product CD or on via the Utilities tab of the 515RTAENI web user interface Use the Rockwell EDS Hardware...

Page 41: ...iver and click the Who Active button 5 After clicking the Who Active button select the 515RTAENI gateway and click OK 6 Then verify that the Comms Path is set to the 515RTAENI and then click Apply and OK NOTE If you get a 0x10 error it indicates that the serial baud rate or the serial wiring are not correct All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 42: ...he PLC using 515RTAENI NOTE The 515RTAENI Ethernet Status LED will only turn solid green when there are communications taking place Anytime there are no communications for over 5 seconds the LEDs will start flashing red The lights will turn solid green once communication resumes All manuals and user guides at all guides com ...

Page 43: ...ions menu 2 If you already have an Ethernet driver configured and wish to add the 515RTAENI to that driver simply add a new node to the driver with the 515RTAENI s IP address 3 If you do not have an Ethernet driver configured select Ethernet Devices from the Available Driver Types dropdown then click Add New and supply it with a suitable name in the resulting popup 4 Enter the IP address of the 51...

Page 44: ...rror after clicking the Apply button The 0x10 error indicates that either the serial baud rates do not match or there is an issue with the serial cable Verify that the serial baud rate configured in the 515RTAENI is the same baud rate configured in the controller also verify that the serial cable is the correct cable and is properly connected Why are The LEDs flashing red when connected to the 515...

Page 45: ...ation tool to successfully install the file Once the EDS file is installed and the Ethernet and serial settings have been set you should be able to discover the 515RTAENI gateway in RSLinx Figure xx 515RTAENI RSLinx EDS file and Icon file Figure xx Rockwell RSLinx EDS Hardware Installation Tool For PanelView Plus communications setup in RSView verify RSLinx Enterprise finds the 515RTAENI gateway U...

Page 46: ...tion tool select the NetENI connected PCCC devices select the appropriate processor family folder and then choose your PLC from the list in the processor folder and press OK The example screens below show the selection of a MicroLogix 1200 controller All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 47: ...e serial input of the controller using the 515RTAENI gateway If this procedure doesn t work the first time delete the original target and rebuild the Comms as described above IMPORTANT When using a PanelView Plus terminal the Duplicate Packet Detect option in the serial controller must be DISABLED otherwise there may be a loss of communications All manuals and user guides at all guides com ...

Page 48: ...wing to gather data from a SLC 5 03 SLC 5 04 or MicroLogix using the 515RTAENI Create a new item name it and then select a channel to use For Channel selecte the Device Driver of Allen Bradley ControlLogix Ethernet see Figure below o After selecting the Device Driver select the Device Model to use on the channel as MicroLogix 1100 see Figure below o Then just enter the IP address to access it All ...