Ethernet Driver
To configure the RSLinx/RSLogix to use the Ethernet driver, first ensure that you have configured the
515RTAENI to match the serial settings on your serial PLC and that you have configured the Ethernet
Network settings to something suitable to your network.
1.
In RSLinx, select ‘Configure Drivers…’ from the ‘Communications’ menu.
2.
If you already have an Ethernet driver configured and wish to add the 515RTAENI to that driver,
simply add a new node
to the driver with the 515RTAENI’s IP address.
3.
If you do not have an Ethernet driver configured, select ‘Ethernet Devices’ from the ‘Available
Driver Types’
dropdown then
click ‘Add New…’
and supply it with a suitable name in the resulting
popup.
4.
Enter the IP address of the 515RTAENI into the ‘Host Name’ entry for Station 0 and click OK.
5.
Your serial PLC should now be accessible via the Ethernet driver.