Real Time Automation, Inc.
37
1-800-249-1612
150-199
Nodes 150-199 give the email addresses used for message sent to Nodes 50-99.
There is 1 address per message, so each Node is in a 1-1 relationship with the
other.
Email Alarms and Messages, p20.
200
Define URL links. These are shown in the 515RTAENI web in the
Reference Links
tab on the Utility tab. The 515RTAENI does not validate the URL.
The serial controller sends a write message to Node 200 and the URL offset to
define a new link on the Reference Links webpage. Only one link is sent per write
message. The controller uses a 485CIF write, where the URL string data is the
write data, and the Offset value defines which URL link to define. Each URL string
can be up to 45 characters.
Reference Links, p26.
Offset
Link
4
1
6
2
8
3
10
4
12
5
14
6
16
7
18
8
20
9
22
10
201
A Write to Node 201 is used to change the Data Description column displayed on
the Data View webpage. Up to 40 elements can be written, since there are 40
labels. But each element is written as one data transmission. In other words, the
string and the element offset is written 40 different times to write 40 labels. Each
write has the form of label/offset.
Data View Tab, p22.
202
Integer data for display on the Data View webpage is written to Node 202, offset
elements 0 to 27. The Integer data written is displayed in the “Write from
Controller” column.
Data View Tab, p22.
203
Floating-point data for display on the Data View page is written to Node 203,
offset elements 0 through 11. The data written is displayed in the “Write from
Controller” column.
Data View Tab, p22.
204
Controller writes event strings to Node 204. They show up on the
NET ENI Event
Log Values
on the Utility page: it is a place for the serial controller to log events
that can then be viewed in the 515RTAENI Event Log webpage. The Event Log
All manuals and user guides at all-guides.com