background image

EN - 2

 

The following symbols may appear on the instrument  

and in this Instruction Manual :

 

 

Risk of electric shock 

 

Refer to Instruction Manual

 

 

Direct Current (dc)

 

 

Equipment protected throughout by double or reinforced 

insulation

 

 

Battery 

 

Fuse

 

 

Earth 

 

Alternating Current (ac) 

 

Conforms to applicable EU directives 

 Caution  

-

 

Disconnect the test leads from the test points before changing the  

   position of the function rotary switch. 

-

 

Never connect the instrument to a source of voltage with the function  

   rotary switch in 

Ω/ 

;

/

 

A

 /

/

Hz

 

position. 

-

 If possible, do not work alone, so assistance can be given if required. 

-

 Do not expose the instrument to extremes of temperature or high  

   humidity. 

-

 Never set the instrument to the 

 

A function to measure the  

  voltage of a power supply circuit, as it may result in damage to the  
  instrument and the equipment under test. 

Maintenance 

Do not attempt to repair this Instrument. It contains no user-serviceable 
parts. Repair or servicing should only be performed by qualified person-
nel. This instrument should be calibrated yearly, or more frequently if 
used in harsh conditions or if it is suspected of being inaccurate. 
For calibration and repair contact RS Components - the address is 
given at the end of these instructions.

 

 

Cleaning 

Periodically wipe the case with a damp cloth and detergent. Do not use  
abrasives or solvents.

 

Summary of Contents for IDM 61

Page 1: ...Instruction Manual IDM 61 62T Digital Multimeter EN DE ES IT FR IDM 62T...

Page 2: ...rify the instrument is operating correctly by measuring a known voltage before use If in doubt have the instrument serviced Do not apply more than the rated voltage as marked on the instrument between...

Page 3: ...can be given if required Do not expose the instrument to extremes of temperature or high humidity Never set the instrument to the A function to measure the voltage of a power supply circuit as it may...

Page 4: ...EN 3 Measuring AC DC Voltage and Frequency Continuity and Diode Test Black Red Black Red Black Red Black Red Bad Diode Good Diode...

Page 5: ...e To improve the measurement accuracy of a small value capacitor record the reading with the test leads open circuit then substrate the residual capacitance of the Instrument and leads from the final...

Page 6: ...EN 5 Measuring DC AC Current For 62T only Disconnect Temperature C F R DCV...

Page 7: ...EN 6 Manual Ranging and Auto Ranging 10 min Auto Power off Battery Saver Display Hold...

Page 8: ...nse button The LCD display will go blank a tone will sound and the red LED will illuminate momentarily to confirm the instrument is operational 4 Hold the Volt sense button down and move the instrumen...

Page 9: ...and rating given in the specifications Refer to the following figure to replace the fuse Battery Replacement When the low battery indicator appears on the LCD replace the batteries with the type give...

Page 10: ...II 1000V A CAT III 600V for 62T only Pollution Degree 2 Measurement Category l is for measurements performed on circuits not directly connected to mains Examples include Measurements on battery power...

Page 11: ...tions Accuracy is reading number of digits at 23 C 5 C 80 RH DC AC Volts Range AC Accuracy 200 0mV Unspecified 2 000V 1 5 5dgt 50Hz 300Hz 20 00V 200 0V 1 5 5dgt 50Hz 500Hz 750V AC 1000V DC DC Accuracy...

Page 12: ...AC Conversion Type Conversion type and additional specification are same as DC AC Voltage Resistance Range Accuracy Voltage Burden 200 0 200 0K 0 7 3 dgt 2V max 2 000M 1 0 3 dgt 20 00M 1 5 3 dgt Open...

Page 13: ...5 Vac rms 5 Vac rms Frequency 0 01 1digit 2 000MHz 20 00MHz 2 Vac rms 5 Vac rms Overload Protection 600V rms Minimum pulse width 25 ns Duty cycle limits 30 and 70 Capacitance For 62T only Range Accur...

Page 14: ...atteries or damage from abuse neglect accident unauthorized repair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this produ...

Page 15: ...Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokoham...

Reviews: