EN - 1

 

 

Safety Information 

 

Read and understand this Instruction Manual completely before using this 
instrument. Failure to observe the warnings and cautions in this Instruc-
tion Manual may result in injury or death, or damage to the  
instrument and other equipment or property. 
If this instrument is used in a manner not specified in these instructions, 
the protection provided by the instrument may be impaired. 

 

 WARNING 

 

-

 Examine the instrument and probes before use. Do not use the  

   instrument if it is wet or damaged. 

-

 When using test leads or probes, keep your fingers behind the  

  finger guards. 

-

 Remove the test lead from the instrument before opening the  

  battery cover or instrument case. 

-

 Always use the correct terminals, switch position and range for  

  measurements. 

-

 Never attempt a voltage measurement with the test leads inserted  

  into the A input terminals. 

-

 Verify the instrument is operating correctly by measuring a known  

  voltage before use. If in doubt, have the instrument serviced. 

-

 Do not apply more than the rated voltage, as marked on the  

  instrument, between terminals or between any terminal and earth  
  ground. 

-

 Do not attempt a current measurement when the open-circuit  

  voltage is above the fuse protection rating.

 

-

 Only replace a blown fuse with the correct type and rating as specified  

   in this Instruction Manual.

 

-

 Use caution when measuring voltages above 30 Vac rms or 60 Vdc.  

  These voltages pose a shock hazard. 

-

 To avoid incorrect readings that can lead to electric shock, replace the  

  battery as soon as low battery indicator 

<

 appears in the display. 

-

 Disconnect the circuit power and discharge all high-voltage capacitors  

  before making resistance,  current, continuity, diode or capacitance     
  measurements. 

-

 Do not use the instrument in a Hazardous Area or  around explosive  

  gasses or vapours. 

-

 Wear suitable Personal Protective Equipment when working around or  

  near hazardous Live conductors which could be accessible. 

Summary of Contents for IDM 61

Page 1: ...Instruction Manual IDM 61 62T Digital Multimeter EN DE ES IT FR IDM 62T...

Page 2: ...rify the instrument is operating correctly by measuring a known voltage before use If in doubt have the instrument serviced Do not apply more than the rated voltage as marked on the instrument between...

Page 3: ...can be given if required Do not expose the instrument to extremes of temperature or high humidity Never set the instrument to the A function to measure the voltage of a power supply circuit as it may...

Page 4: ...EN 3 Measuring AC DC Voltage and Frequency Continuity and Diode Test Black Red Black Red Black Red Black Red Bad Diode Good Diode...

Page 5: ...e To improve the measurement accuracy of a small value capacitor record the reading with the test leads open circuit then substrate the residual capacitance of the Instrument and leads from the final...

Page 6: ...EN 5 Measuring DC AC Current For 62T only Disconnect Temperature C F R DCV...

Page 7: ...EN 6 Manual Ranging and Auto Ranging 10 min Auto Power off Battery Saver Display Hold...

Page 8: ...nse button The LCD display will go blank a tone will sound and the red LED will illuminate momentarily to confirm the instrument is operational 4 Hold the Volt sense button down and move the instrumen...

Page 9: ...and rating given in the specifications Refer to the following figure to replace the fuse Battery Replacement When the low battery indicator appears on the LCD replace the batteries with the type give...

Page 10: ...II 1000V A CAT III 600V for 62T only Pollution Degree 2 Measurement Category l is for measurements performed on circuits not directly connected to mains Examples include Measurements on battery power...

Page 11: ...tions Accuracy is reading number of digits at 23 C 5 C 80 RH DC AC Volts Range AC Accuracy 200 0mV Unspecified 2 000V 1 5 5dgt 50Hz 300Hz 20 00V 200 0V 1 5 5dgt 50Hz 500Hz 750V AC 1000V DC DC Accuracy...

Page 12: ...AC Conversion Type Conversion type and additional specification are same as DC AC Voltage Resistance Range Accuracy Voltage Burden 200 0 200 0K 0 7 3 dgt 2V max 2 000M 1 0 3 dgt 20 00M 1 5 3 dgt Open...

Page 13: ...5 Vac rms 5 Vac rms Frequency 0 01 1digit 2 000MHz 20 00MHz 2 Vac rms 5 Vac rms Overload Protection 600V rms Minimum pulse width 25 ns Duty cycle limits 30 and 70 Capacitance For 62T only Range Accur...

Page 14: ...atteries or damage from abuse neglect accident unauthorized repair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this produ...

Page 15: ...Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokoham...

Reviews: