installation

Location
It is important to locate the detector 

so that any occupants fall within the 

detection zone shown on the diagram.

Do not block the sensor with a door or 

other object.

Do not install above a radiator or other 

heat source.

Avoid direct sunlight entering the sensor.

2

Detection zone

This product should be installed in 

accordance with the current IEE wiring 

regulations. If in doubt consult a qualified 

electrician.

Use the extender if there is less than 

25mm free space.

REMEMBER – put the wires through 

the extender before connecting.

Compatible with all BS4662 dimensions  

back boxes.
Remove top and bottom lugs if fitted. 

25mm

Do not overtighten

5M

4.5M

Summary of Contents for 796-2015

Page 1: ...ngle gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting heating and ventilation loads up to 10A GIPDC B User Guide ...

Page 2: ...t source Avoid direct sunlight entering the sensor 2 Detection zone This product should be installed in accordance with the current IEE wiring regulations If in doubt consult a qualified electrician Use the extender if there is less than 25mm free space REMEMBER put the wires through the extender before connecting Compatible with all BS4662 dimensions back boxes Remove top and bottom lugs if fitte...

Page 3: ...ng If more than one detector is required to switch the lighting e g at the top and bottom of a staircase they can be wired in parallel as in the diagram wiring May have red or brown sleeve May have red or brown sleeve Com L1 Neutral Black or Blue Live Red or Brown Earth Yellow Green Strapper Yellow or Grey ...

Page 4: ...is occupied The unit will reset to automatic operation after a period of time Press for more than 5 seconds to de activate see Activate section controls and basic operation daylight setting battery indicator PIR lens toggle switches Remove front cover Use a flathead screwdriver or similar to gently prise off the cover and replace with new one by snapping on to switch ON 1 2 TOP ...

Page 5: ...e enters the corridor n nobody in the room for 20 minutes n there is little or no natural light suggested settings BEDROOM AREA Shallow back box Different wiring colo 2 way wiring Refer to main data ctronics co uk Remove top and bottom lugs if fitted Do not overtighten Live supply Lamps May have red or brown sleeve Manual on turns on when top button pressed Auto off turns off when nobody in the ro...

Page 6: ...nd off using the switches as shown in the setup section When activated security mode is used to switch on lighting when it gets dark giving the impression a house is occupied When the unit senses that it is dark outside the lights will automatically switch on for a period of 2 hours then switch off batteries The internal battery should last in excess of 3 years dependent on usage When it needs rep...

Page 7: ...7 battery replacement 1 Remove front cover 2 Remove switch cover 3 Lever out battery 4 Replace battery 5 Push into holder 6 Replace switch cover 7 Replace front cover 8 Activate ...

Page 8: ...ights never turn off The lights will only turn off after no movement is detected for the time period Is the time period set too long Voltage 230VAC 10 Frequency 50Hz Temperature 0ºC to 35ºC Power 10A Compliance BS EN60669 2 1 BS EN55015 EU registered design no 000638069 0003 000638069 0004 troubleshooting ratings 8 WD411 issue 1 FM 45789 EMS 534520 ...