S1
&
S2 & S3 / EN
24
Maximum measurement time :
>5A for max.3 minutes with at least 20 minutes rest time.
>10A for max.30 seconds with at least 10 minutes rest time.
Frequency Response :
45 ~ 500Hz (Sine Wave)
Overload Protection :
Fuse AC/DC 11A
(13) Resistance
Range
OL Reading
Resolution
Accuracy
600.0
Ω
660.0
Ω
0.1
Ω
±
(0.9% + 5D)
6.000k
Ω
6.600k
Ω
0.001k
Ω
±
(0.9% + 2D)
60.00k
Ω
66.00k
Ω
0.00k
Ω
±
(0.9% + 2D)
600.0k
Ω
660.0k
Ω
0.1k
Ω
±
(0.9% + 2D)
6.000M
Ω
6.600M
Ω
0.001M
Ω
±
(0.9% + 2D)
40.00M
Ω
*
44.00M
Ω
0.01M
Ω
±
(1.5% + 5D)
* There is a little rolling less than ±50 digits when measuring
>10.00 M
Ω
.
Overload Protection :
AC/DC 1000V
(14) Continuity
Range
OL Reading
Resolution
Accuracy
600.0
Ω
660.0
Ω
0.1
Ω
±
(0.9% + 5D)
Continuity :
Built-in buzzer sounds when measured resistance
is less than 20Ω and sounds off when measured resistance is
more than 200Ω, Between 20Ω to 200Ω the buzzer maybe
sound or off either.
Continuity Indicator :
2.7K Tone Buzzer
Response Time of Buzzer :
< 100msec.
Overload Protection :
AC/DC 1000V
(15) Diode
Range
OL Reading
Resolution
Accuracy
1.500V
1.550V
0.001V
±
(0.9% + 2D)
Open Circuit Voltage :
Approx. 1.8V
Overload Protection :
AC/DC 1000V.