background image

While a parameter is selected, by pressing         key, parameter value can be displayed. This parameter can be changed with            keys. If no operation 
performed for 3 seconds or  during this time,       key is pressed while parameter value displayed, parameter name will be displayed again. While parameter name 
displayed, if by pressing together           keys, "Running Mode" is entered. 

If          keys are pressed together for  2 seconds                 is displayed and “User Menu” is entered, then first parameter’s name is displayed in the user menu.

While in  "Running Mode", if             keys are pressed together for 2 seconds, 

 

Loc

 message is displayed and the keys are locked. If the keys are locked

             keys are pressed for 2 seconds again, 

unL

 message is displayed and keys are unlocked. While keys are locked  and  if       key is pressed, set value can be 

displayed but can not be changed. While the keys are locked and if any key is pressed 

( except        key )

,  

Loc

  message appears.

uPL

Hy

5

C.Fos

C.Fos

C.Fo

5

uPL

6. The Hidden Menu

While in “User Menu”,  if      key is pressed for 7 seconds the           message is displayed and hidden 
menu is enterd and then  

upl

 

parameter is displayed. Selected the parameter’s value can be 

displayed by pressing      key and can be changed with          keys. Parameter accessing and saving 
functions can be performed like a "User Menu". All parameters can be accessed from this menu.      

 If              keys are pressed together for 2 seconds; parameter is transferred to the user menu. In this way 
up to 8 parameters can be transferred to the "User Menu".

7. How can we to transfer parameter between menus?

  Program Mode

ERROR MESSAGES

 

  

P

5

C

 Pfa

ALARM SITUATION

5. Changing Parameter Values

 4. Activating / Inactivating The Control Outputs

    

    

    

C.dI

5

C

E

NB

 When in the "Running mode", if        key is pressed for 2 seconds, 

C.dI5

 message is displayed and control outputs becomes to the inactive position, the device 

works as the indicator. When the control outputs are disabled; if       key is pressed for 2 seconds  

C.EnB

   is disabled and the device continues to control function.    

1000

-

24.0

The control ouput becomes inactive.

The control output becomes active.

EA

SET

SET

SET

SET

In “User Menu” if            keys are pressed together for 2 seconds, parameter is removed from “User Menu.
When a parameter is displayed “User Menu”,  

°

F LED lights up in hidden menu. If there is no parameter in 

"User Menu",   

nP

  message is displayed.

SET

1000

-

24.0

SA

Means, thermostat probe is broken.

 Temperature value is higher than the scale.

Means, thermostat probe is short circuit.

Temperature value is lower than the scale.

1.

 Measurements shown flashes when the alarm condition occurs and if 

5ND

 parameter is not  

0

 , audible warning is heard.

2.

 External alarm is active but the outputs are unaffected.

3.

 External alarm is active and in this state, specifies that the relay outputs are turned off (off state).

    While warning, by pressing       key, audible warning can be temporarily disabled.  

FACTORY SETTINGS

If      key is held down while the device is powered up, 

 

d.PAr

 message appears and factory parameters restored.

                

DEFROST

 LED

 

:

 

With the defrost lights up.

SET

     

FAHRENHEIT LED :

 

In parameter value or the measured temperature value “

°

F”

 unit while this LED 

       lights up. In the hidden menu at the same time the user menu parameter is shown the LED lights up.

                

COMPRESSOR LED : 

If compressor output is active, this LED lights up. While these compressor

              delays expected, this LED flashes.

In "Running Mode", indicates the set value.
In “Programming Mode”, indicates the selected parameter value.

                

While in "Programming Mode", provides the transition to the next parameter. If parameter is being 

              adjusted, it increases parameter’s value. Constantly holding this key, the parameter value rapidly
              increases.

                

While in "Programming Mode", provides the transiton to the previous parameter. If parameter is

              being adjusted, it decreases parameter’s value. Constantly holding this key,the parameter value
              rapidly decreases.

                

HEATING LED 

:

 

Heating is being checked; while the output is active, the LED lights.

 

 FRONT PANEL COMMANDS

1. Viewing and  Changing The Set Value

Measurement 

value

-

30.0

-

29.9

-

30.0

1000

-

24.0

SET

While in "Running mode", if         key is pressed set value is displayed for 3 seconds. While in this case, the set value is changed with          keys.

SET

Loc

unl

1000

-

24.0

SET

Keys are locked.

Keys are unlocked.

SET

SET

SET

SET

 2. Locking and Unlocking Keys

 3. Manuel Defrost Process

While in the "Running Mode", if       key is pressed for 2 seconds, defrost process starts manually. If   

parameter is 

 

0

 , manual defrost will be inactive.      

d.dur 

*

 When in the "Running Mode", if the control outputs 

are  inactive, 

oFF

 message appears periodically.

°F

.

Measurement 

value

Measurement 

value

    While warning, by pressing any key, audible warning can be temporarily disabled.  

2/3

      

1241045/46-E-01-161006