RPSwaterpumps.com
PUMP TROUBLESHOOTING
No Lights On Pump
Low or no power
To pump
Check Connections, Soft Reset of Controller, Check batteries for
low voltage
Pump Doesn’t Start
Pipe is
blocked
Ensure valves are open to clear airlocks
Pump Doesn’t Stop
Check for leaks, Turn down
pressure
Small leaks in plumbing are the most common, check around
outlet cover, Turn down pressure setting
Pump Sputters
Pump not properly primed or
air entering system
Prime pump and remove all air from system, check inlet pipes for
leaks, Install foot valve for suction applications
Settings may have been
changed
Reset to factory defaults
Press and hold “MODE” for three seconds
E01
Low input voltage
Check input voltage, Check battery voltage
E02
Over voltage input
Ensure input voltage is less than 140V AC
E03
Pressure sensor error
Hard Reset, Replace pressure sensor
E04
Pump over temperature
Remove pump from direct sun, Improve ventilation
E05
Pump Overload
Ensure water is fairly clear (no mud or large debris)
E06
Display over temperature or
sensor failure
Remove from direct sun, Improve ventilation, Hard reset, Contact
RPS
E07
Not Used
n/a, Hard Reset
E08, E09
Motor phase mismatch, Over
current
Motor not operating at commanded speed, check for obstructions,
check for stuck impellers
E10
Startup fault
Hard Reset, Contact RPS to check for impeller obstructions
E11
Motor communication error
Check for damage to motor wires, Hard Reset, Contact RPS
E12
Not used
n/a, Hard Reset
E13
Display communication error
Hard Reset, Contact RPS
Hard Reset
Unplug pump, wait 60 seconds,
plug pump back in.
Summary of Contents for Eco-Steady Booster Pump BP05
Page 2: ...RPSwaterpumps com ...
Page 3: ...RPSwaterpumps com ...