RPSwaterpumps.com
PUMP MODES
MODE to select the working mode:
1. NORMAL (most common)
Increases the water pressure or draws water up
from below pump and pressurizes. This is the
normal booster pump application.
1.0 - 2.0 Low Pressure
2.0 - 3.0 Medium Pressure
3.0 - 4.0 High Pressure
1 kg/cm² = 14.5 psi
Note: Pump shutoff will become unstable if
pressure is set too high. If pump will not shut-off,
reduce pressure setting
2. BOOST
Increases poor water pressure. For example
increasing 20 PSI water pressure to 45 PSI on a the
second story of a house.
3. TIMER
Operates for the specified amount of time and then
stops the pump. Used for filling elevated tanks.
BP1, BP2, LOCK / UNLOCK Hold UP and
DOWN arrows together
SYSTEM RESET OPTIONS:
POWER RESET:
Controller Soft Reset: Turn off controller power button (display will stay on if solar panels
are connected), wait 60 seconds and turn power button back on.
Controller Hard Reset: Disconnect solar panels and batteries. Wait 60 seconds, connect
batteries, then solar panels.
Pump Hard Reset: Unplug pump, wait 60 seconds, plug pump back in.
PUMP SETTINGS RESET:
Pump Factory Reset: Press and hold MODE for 3 seconds, all factory parameters will be
restored to factory settings.
TP750 - LOCK / UNLOCK
Hold + and - together
ADD 110V, TPP
AND 3HP
DISPLAYS!
Summary of Contents for Eco-Steady Booster Pump BP05