04-960 AND 04-964-RZ ASSEMBLY - 6 OUTLET MANIFOLD
To assemble the Six Outlet Manifold, first
thread the 04-915 Pressure Gauge into the
04-965 6 Outlet Manifold and tighten.
Thread all six Couplers into the 04-965
Manifold and tighten.
Thread the completed Six Outlet Manifold
assembly into filter lid and tighten.
FIGURE 3.1
FIGURE 3.2
FIGURE 3.3
FIGURE 3.4
Thread the 04-916 Pressure Relief Valve
into the lid and tighten.