The fuses are located inside
two carriers, each marked
with an arrow pointing to the
right. These carriers can be
pulled out with the tip of a
screwdriver blade or a pair of
needle nose pliers (image 4).
O n c e t h e c a r r i e r s a r e
removed, the fuses can be
pulled out with your fingers.
Replacing the fuse carriers is
the reverse of removal. They
can only be inserted with the
arrow facing to the right and
they should go in very easily.
CAUTION!
Never attempt to bypass a fuse
or use one of a higher rating!
Not only is this an unsafe
practice, but it will void the
factory warranty.
Voltage Changeover
The power supply can be set
to operate from voltages
ranging from 100 to 240 volts
AC. For 230V operation, use
the 240V setting. A small
window at the rear of the
Input Power Module will
display the current voltage
setting. To change operation
to a different AC voltage
requires repositioning a
selector drum within the
module. Remove the power
cord and open the module
door in the same manner as
to access the fuses. The drum
can be removed
Image 3
Image 4
Image 5
Image 6
9
Summary of Contents for R-122V
Page 31: ...Polar Pattern Frequency Response 30 ...