16
TROUBLESHOOTING
Problem:
Condition:
Solution suggested:
Burner won’t
light
Control knob is not in Maximum position (big
flame).
Turn control knob in Maximum position (big flame).
LPG cylinder valve is closed / Empty.
Open the valve / Replace LPG cylinder with a new one.
Blockage in the injector.
Clean or replace injector.
Air in the gas circuit.
Open gas line and bleed it (pressing
control knob in) for not over 1 minute or until you smell g
as.
Low gas pressure.
Replace LPG cylinder with a new one.
Igniter fails.
Use match to light burner; change battery or obtain new
ignite and replace it
.
Burner won’t
stay lit
Dirty build up around burner.
Clean dirty around the burner.
Low flames or not full running around the
burner.
Flame spreader holes partially closed; clean the burner.
Thermocouple is not operating correctly.
Replace thermocouple (FSD).
Low Gas pressure.
Replace LPG cylinder with a new one.
Burner flame is
low
Note: Do not
operate appliance
below 5 ˚C
Outdoor temperature is greater than 5 ˚C
and LPG cylinder is less than 25 % full.
Replace LPG cylinder with a new one.
Gas pipe is bent or kinked.
Straighten hose and perform leakage test on gas pipe.
Control knob is fully Maximum position (big
flame).
Turn control knob to” OFF" position (full disk), let cool to
room temperature and check burner and
orifices for blockage.
Carbon build-up
Dirty or film on burner.
Clean burner.
Flash back
(flame
inside burner)
Burner ports are blocked.
Switch OFF the appliance. Close LPG cylinder valve. Wait 2
minutes, following the ignition procedure. Ignite burner. If
problem continuous, switch-off. Contact your dealer.
Thick black
smoke
Blockage in the burner.
Turn control knob to "OFF" position, let the appliance to
cool at room temperature and remove
blockage and clean burner inside and outside.