12
•
Connect the hose to the appliance and the regulator. Tighten the screw of the hose clamp with a screwdriver.
(see below Figure9)
(Picture 9)
OPERATING INSTRUCTIONS
Lighting
Before ignite the appliance, perform “Leakage Testing” in a well ventilated area (outdoor). At first use and after
every LPG cylinder substitution, appliance gas circuit must be purged of the inside air before igniting! To do this,
turn the control knob counter-clockwise to the ignition position and push it holding for 1 minute before
attempting ignition.
1.
Make sure that LPG cylinder, full 4/5 its capacity, contains proper LPG Gas (refer to Technical Data on page
2).
Turn LPG cylinder valve in full “ON” position and close LPG compartment panel.
2.
Make sure that burner control knob is in “OFF” position (full disk).
3.
Push the control knob and keep pressing while turning counter-clockwise to the corresponding Maximum
position (big flame). At the same time push the ignition button (star). Push the ignition will spark
automatically (it is possible to ignite the appliance even with proper lit long match, approaching carefully
the burner managing in the same way).
4.
When the burner is lit in Maximum position (big flame), stop pushing ignition button (star) and keep the
control knob pressed but not over 20 seconds to heat the thermocouple (FSD); then release it (first ignition
take generally more time, because gas circuit is full of air).
5.
If the burner does not keep lit, wait 5 minutes and then repeat steps 3 and 4.
6.
Burner now is lit in Maximum position (big flame).